Enter the diameter, the interference, the clearance and the material to get the temperature rise needed to heat the hub or to cool the shaft.

Updated on
Your inputs
mm

Value out of range

mm

Value out of range

mm

Value out of range

°C

Value out of range

°C

Value out of range

Results

Temperature change needed

137 K

Temperature of the heated hub
157 °C
Temperature of the cooled shaft
-117 °C
Growth of the diameter at that temperature
80.0 µm
Margin below the maximum heating temperature
93 °C
Share of the drop that dry ice (−78 °C) provides
72 %

The shrink fit calculator gives the temperature change, the temperature of the heated hub, the temperature of the cooled shaft, the growth of the diameter, the margin below the maximum heating temperature and the share of the drop that dry ice provides.

How the calculation works

  • Enter the diameter, the interference and the clearance wanted for the assembly, on the diameter.
  • Choose the material of the part that will be heated or cooled and enter the room temperature.
  • Enter the maximum heating temperature allowed for the part.

Example

A fit of 50 mm with 0.05 mm of interference and 0.03 mm of clearance needs a change of 137 K. The hub is heated to 157 °C, which grows its diameter by 80.0 µm and leaves a margin of 93 °C under the limit. Alternatively, the shaft is cooled to -117 °C, and dry ice provides 72 % of the drop needed.

Why it matters

The calculator helps machinists, mechanics, maintenance teams and designers who mount bearings, gears, pulleys and bushings with an interference fit, and who need to know how hot or cold to bring a part to assemble it by hand or press.

Good to know

Calculate with the diameter of the part that changes and the coefficient of the material, and heat uniformly: a part heated unevenly distorts. The values used are averages between 20 and 200 °C, and the coefficient rises a little with temperature, so the result is slightly pessimistic. Check the tolerance of the diameters, because a small error in the interference changes the temperature a lot. After assembly, the interference gives the holding torque and the contact pressure, which you can check with a press-fit calculation. Never heat sealed bearings or parts with seals beyond the limit of the maker, and wear gloves and eye protection with liquid nitrogen.

The thermal expansion calculator gives the growth of a length, the press fit calculator gives the pressure and the force of the interference, the bolt torque calculator handles another way of holding parts and the shaft key calculator sizes the key that a fit can replace.

Frequently asked questions

How do I calculate the temperature for a shrink fit?

The diameter changes by Δd = α × d × ΔT, where α is the coefficient of thermal expansion. To assemble, the hub must grow by the interference plus the clearance you want, so ΔT = (interference + clearance) / (α × d). For a 50 mm steel fit with 0.05 mm of interference and 0.03 mm of clearance, ΔT is 137 K, so the hub is heated to about 157 °C from 20 °C.

Should I heat the hub or cool the shaft?

Heating the hub in an oven or with an induction heater is the simplest and gives large changes of temperature. Cooling the shaft in dry ice (−78 °C) or liquid nitrogen (−196 °C) avoids heating the hub, and is used when heat would damage seals, coatings or the heat treatment. A mix of the two reduces the temperature extremes and the time to assemble.

What temperature limits should I respect?

Do not exceed the tempering temperature of the steel, often 150 to 250 °C for hardened parts, and keep the hub below the point where oil burns or paint damages. For aluminium, stay under 150 to 200 °C. If the required temperature is higher than the limit, use cooling too, or lower the interference.

How much time do I have to assemble?

The part gives off heat fast, and the clearance is lost within seconds for thin parts. Prepare the tools, align the parts and assemble quickly, in a few seconds. Include a safety margin in the clearance and measure the temperature right before the insertion.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.