Enter the dimensions of the sample and the standpipe, the heads at the start and the end and the time of a falling head permeability test to get the hydraulic conductivity of the soil in cm/s, ft/day and in/s.

Updated on
Your inputs
in

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

s

Value out of range

Results

Hydraulic conductivity k

0.000203 cm/s

Slow drainage: silt or fine sand
Hydraulic conductivity k
0.576 ft/day
Hydraulic conductivity k
0.000080 in/s

How fast does water move through a soil? The soil permeability test calculator works out the hydraulic conductivity k from a falling head test: the dimensions of the sample and of the standpipe, the heads at the start and at the end, and the time. It gives k in cm/s, ft/day and in/s, with a classification of the soil.

How the calculation works

  • Enter the diameter and the length of the soil sample in the permeameter, and the diameter of the standpipe that carries the water above it.
  • Enter the water head at the start and at the end of the test, measured from the outlet level, and the duration between the two readings.
  • The calculator applies the falling head equation k = (a L) / (A t) × ln(h₁ / h₂), where a is the area of the standpipe and A the area of the sample.
  • It gives the hydraulic conductivity k in cm/s, in ft/day and in in/s, and classifies the soil from clean sand to clay.

Example

A sample of 4 in of diameter and 4.7 in of length is tested with a standpipe of 0.4 in of diameter. The head falls from 40 in to 24 in in 300 s. The area ratio is (0.4 / 4)² = 0.01. The conductivity is k = 0.01 × 4.7 / 300 × ln(40 / 24) = 8.0 × 10⁻⁵ in/s, which is 0.000203 cm/s or 0.576 ft/day. This is typical of a silt or a fine sand with slow drainage.

Why it matters

The calculator helps geotechnical technicians, civil engineering students and drainage designers to reduce the data of a permeameter test, to check a result against typical values and to compare the soils for a drain, a pond or a septic field. It removes the logarithm and the unit conversions from the lab sheet.

Good to know

Saturate the sample before the test and remove the air. Take several readings and use consistent heads. Use the thin standpipe for a clay and the thick one for a silty sand. Correct the result for the temperature of the water, and remember that the conductivity of the soil in place can be 10 to 1,000 times that of the lab sample.

Darcy’s law calculator gives the flow through a soil, the soil compaction calculator covers the fills, the French drain calculator sizes a drain and the rain garden calculator uses the infiltration of the soil.

Frequently asked questions

What is the falling head test?

The falling head test measures the hydraulic conductivity of fine soils such as silts and clays, which are too slow for a constant head test. A soil sample is placed in a cylinder, and water flows through it from a thin standpipe above. The water level in the standpipe falls with time, and the rate of fall depends on the conductivity of the soil. Measuring two levels and the time between them gives k.

Where does the equation come from?

At any time, the flow through the sample, q = k A h / L, is equal to the rate at which the level falls in the standpipe, q = −a dh/dt. Separating the variables and integrating from h₁ to h₂ over the time t gives k = (a L)/(A t) × ln(h₁ / h₂). The area ratio a/A is the square of the ratio of the diameters of the standpipe and the sample. A thin standpipe gives a measurable fall for a low conductivity.

What are the typical values?

Clean gravel has a conductivity above 0.1 cm/s, and clean sand between 0.1 and 0.001 cm/s. Fine sand and silty sand are between 0.001 and 0.00001 cm/s, silt between 0.00001 and 0.000001 cm/s, and clay lower than 0.0000001 cm/s. The difference between gravel and clay is of more than seven orders of magnitude, so the permeability controls the design of drains, dams and landfills.

What are the limits of this calculator?

It applies to a saturated sample in a rigid-wall permeameter, with laminar flow. It does not include the correction for the temperature, which changes the viscosity of the water, the air bubbles in the sample, the leakage along the walls, the fines that migrate during the test or the difference between the lab sample and the soil in place, which has layers and cracks. Report the result at 20 °C according to the test standard.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.