The trash rack head loss calculator gives the Kirschmer head loss of a bar rack, clean and blocked, the velocity between the bars, the number of bars and the gross area of the rack, from the bar shape and size, the spacing, the approach velocity, the angle and the flow.
How the calculation works
- Choose the shape of the bars and enter their thickness, the clear spacing, the approach velocity and the angle of the rack.
- Enter the share of the rack blocked by debris, the design flow and the width of the rack.
- The calculator gives the head loss clean and blocked, the velocity between the bars, the number of bars and the gross area.
Example
A rack of rectangular bars of 1/2 in with a clear spacing of 1.5 in, tilted at 75 degrees, has an approach velocity of 2 ft/s. Clean, the Kirschmer head loss is 2.42 × (0.5 / 1.5)^(4/3) × 2² / 64.4 × sin 75° = 0.40 in. With 20 % of the area blocked, the velocity grows to 2.5 ft/s, the velocity between the bars is 3.33 ft/s and the head loss is 0.63 in. A flow of 30 cfs needs a gross area of 15.0 ft², and a rack 8 ft wide has 47 bars.
Why it matters
The calculator helps civil and hydraulic engineers, designers of culverts, intakes and pumping stations, and operators to size a trash rack, to see the effect of the bar shape and the spacing, and to check the head loss when the rack is partly blocked.
Good to know
Choose the clear spacing for the debris and the use of the intake, and the approach velocity low enough to keep the head loss small and to let the debris lie on the rack, not stick to it. Use streamlined bars for a long rack, slope it for the rake, and keep the water level at the rack above the top of the opening with the blockage you accept. Inspect and clean the rack before the storm season.
Related tools
The broad-crested weir calculator gives the flow over a weir, the culvert pipe size calculator sizes a culvert, the pipe flow velocity calculator gives the velocity in a pipe and the grate inlet capacity calculator gives the flow of a grate in a street.