Skip to content
Omnikalc

Trash rack head loss calculator (Kirschmer)

Enter the bar shape, the thickness, the spacing, the approach velocity, the angle and the blockage to get the head loss, the bar velocity and the area of the rack.

Updated on
Your inputs
in

Value out of range

in

Value out of range

ft/s

Value out of range

°

Value out of range

%

Value out of range

cfs

Value out of range

ft

Value out of range

Results

Head loss with the rack blocked

0.63 in

Head loss with a clean rack
0.40 in
Velocity between the bars
3.33 ft/s
Number of bars across the width
47
Gross area of the rack
15.0 ft²

The trash rack head loss calculator gives the Kirschmer head loss of a bar rack, clean and blocked, the velocity between the bars, the number of bars and the gross area of the rack, from the bar shape and size, the spacing, the approach velocity, the angle and the flow.

How the calculation works

  • Choose the shape of the bars and enter their thickness, the clear spacing, the approach velocity and the angle of the rack.
  • Enter the share of the rack blocked by debris, the design flow and the width of the rack.
  • The calculator gives the head loss clean and blocked, the velocity between the bars, the number of bars and the gross area.

Example

A rack of rectangular bars of 1/2 in with a clear spacing of 1.5 in, tilted at 75 degrees, has an approach velocity of 2 ft/s. Clean, the Kirschmer head loss is 2.42 × (0.5 / 1.5)^(4/3) × 2² / 64.4 × sin 75° = 0.40 in. With 20 % of the area blocked, the velocity grows to 2.5 ft/s, the velocity between the bars is 3.33 ft/s and the head loss is 0.63 in. A flow of 30 cfs needs a gross area of 15.0 ft², and a rack 8 ft wide has 47 bars.

Why it matters

The calculator helps civil and hydraulic engineers, designers of culverts, intakes and pumping stations, and operators to size a trash rack, to see the effect of the bar shape and the spacing, and to check the head loss when the rack is partly blocked.

Good to know

Choose the clear spacing for the debris and the use of the intake, and the approach velocity low enough to keep the head loss small and to let the debris lie on the rack, not stick to it. Use streamlined bars for a long rack, slope it for the rake, and keep the water level at the rack above the top of the opening with the blockage you accept. Inspect and clean the rack before the storm season.

The broad-crested weir calculator gives the flow over a weir, the culvert pipe size calculator sizes a culvert, the pipe flow velocity calculator gives the velocity in a pipe and the grate inlet capacity calculator gives the flow of a grate in a street.

Frequently asked questions

What is the Kirschmer equation?

The Kirschmer equation gives the head loss through a bar rack as hL = β (t / b)^(4/3) × (v² / 2g) × sin θ, where t is the thickness of the bar, b the clear spacing between the bars, v the approach velocity upstream of the rack, g the gravity and θ the angle of the rack from the horizontal. The factor β depends on the shape of the bar and ranges from 0.76 for a teardrop shape to 2.42 for a rectangle.

What are the values of β?

The usual values are 2.42 for a rectangular bar, 1.83 for a rectangular bar with a semicircular upstream face, 1.79 for a circular bar and 0.76 for a teardrop shape. A streamlined bar loses a third to a quarter of the head of a rectangular one. A thick bar with a narrow spacing loses much more, because the ratio t / b is raised to the power of 4/3, so the choice of the spacing has the strongest effect.

How is blockage handled?

Debris blocks part of the area and raises the velocity through the open part. The calculator divides the approach velocity by the open share to get the velocity in a blocked rack, and uses it in the equation. Designers often check the rack at 50 % blocked, and the intake must be sized for the water level with this head loss, with a rake or a cleaning machine to avoid it in practice.

What does the calculator leave out?

The calculator uses the approach velocity and does not include cross bars, supports, the skew of the flow, or the loss of the bars that are not parallel to the flow. For the loss of fine screens and for the rack of a pumping station or a hydroelectric intake use the equation of the manufacturer or the standard, and choose the velocity for the use, for example a low velocity to protect fish.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.