Skip to content
Omnikalc

Grate inlet capacity calculator: how much flow a storm drain grate can take

Enter the grate size, the open area, the ponded depth, the clogging allowance and the design flow to get the weir capacity, the orifice capacity, the inlet capacity and its margin over the design flow.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

in

Value out of range

%

Value out of range

Value out of range

cfs

Value out of range

Results

Inlet capacity (the smaller of the two)

1.73 cfs

Capacity as a weir (perimeter flow)
1.73 cfs
Capacity as an orifice (open area flow)
2.65 cfs
Inlet capacity over the design flow
1.73
The inlet has a margin over the design flow
Inlet capacity
774 gpm

The grate inlet capacity calculator gives the flow a storm drain grate can take from its size, its open area, the ponded depth and a clogging allowance, as a weir and as an orifice, and compares the smaller of the two with the design flow.

How the calculation works

  • Enter the length and the width of the grate, and the share of open area given by the manufacturer.
  • Enter the ponded depth over the grate, usually the depth at the curb or the gutter, and a clogging allowance of 25 to 50%.
  • The calculator finds the capacity as a weir Q = 3.0 P d^1.5 on the clear perimeter, and as an orifice Q = 0.67 A √(2 g d) on the clear open area.
  • The inlet capacity is the smaller of the two, shown in cfs and gpm and compared with the design flow.

Example

A grate of 2 ft × 1.5 ft has 60% open area and a clogging allowance of 50%, with a ponded depth of 3.6 in (0.3 ft). The clear perimeter is 2 × 3.5 × 0.5 = 3.5 ft, and the weir capacity is 3.0 × 3.5 × 0.3^1.5 = 1.73 cfs. The clear open area is 3 × 0.6 × 0.5 = 0.9 ft², and the orifice capacity is 0.67 × 0.9 × √(2 × 32.2 × 0.3) = 2.65 cfs. The inlet capacity is 1.73 cfs, or 774 gpm, which is 1.73 times a design flow of 1 cfs.

Why it matters

The calculator helps civil engineers, site designers, contractors and students to check the number and size of the inlets of a parking lot, a street or a yard, to see the effect of clogging and the ponded depth and to avoid flooding. It gives a quick check before the use of a stormwater software.

Good to know

Use a clogging allowance suited to the site, and the depth allowed by the local rules, which is often 3 to 6 in (75 to 150 mm) in a parking lot. Use the open area from the manufacturer and not the gross area. Check the pipe below the inlet and its capacity too. At low points, provide an overflow route for larger storms, and follow the standards of the local authority.

The weir flow calculator and the orifice flow calculator give the base equations, the rational method calculator gives the design flow and the detention time calculator covers stormwater basins.

Frequently asked questions

How does a grate inlet work?

At low ponded depths the water flows over the edges of the grate like a weir, and the capacity grows with the perimeter and with the depth to the power 1.5. When the depth grows, the grate works like an orifice with a flow through its open area, which grows with the square root of the depth. The real capacity is the smaller of the two, because the inlet acts as the more restrictive of the two controls.

What clogging allowance should I use?

Leaves, debris, trash and sediment reduce the clear opening of a grate. Design manuals recommend reducing the capacity by 25 to 50% for a street grate, and more in areas with trees and heavy debris. A grate in a sag point, where all the water must enter, is more critical and needs a larger allowance or a double inlet. The factor reduces both the perimeter and the open area in this calculator.

What are the weir and orifice coefficients?

The weir coefficient is 3.0 in imperial units (1.66 in SI) for a free-flowing weir on a clear perimeter, and the orifice coefficient is 0.67, as given by the FHWA HEC-22 manual for grate inlets in a sag. The values are typical and the manufacturers of inlets publish test data for their own grates. A curb opening inlet has its own equations, and a combination inlet is more complex.

What is the design flow?

The design flow comes from the rational method or a hydrograph for the contributing area and the design storm, as the 10-year storm for a street. The flow that is not intercepted by the inlet continues down the gutter to the next inlet, a carryover. At a sag the inlet must take all the flow, and it must be checked also for a larger storm to avoid flooding of the road.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.