Water quality volume (WQv) calculator: how much runoff must a stormwater practice treat?

Enter the drainage area, the impervious cover, the water quality storm and the facility depth to get the runoff coefficient, the water quality depth, the volume to treat and the surface area of the facility.

Updated on
Your inputs
acres

Value out of range

%

Value out of range

in

Value out of range

ft

Value out of range

Results

Water quality volume

12,850 ft³

Runoff coefficient Rv
0.590
Water quality depth
0.71 in
Water quality volume in acre-feet
0.295 acre-ft
Surface area of the facility
4,283 ft²

The water quality volume calculator gives the volume of runoff that a stormwater practice must treat, the WQv, from the impervious cover, the drainage area and the rainfall of the water quality storm, with the surface area of the facility.

How the calculation works

  • Enter the drainage area of the site and its impervious cover in percent.
  • Enter the rainfall of the water quality storm, usually the 90th percentile storm of the region (about 1 in in many places).
  • Enter the average depth of the treatment facility, for example a pond, a basin or a bioretention area.
  • The calculator finds the runoff coefficient Rv = 0.05 + 0.009 I, the water quality depth, the water quality volume (WQv) and the surface area needed at the chosen depth.

Example

A site of 5 acres has 60% impervious cover. The runoff coefficient is Rv = 0.05 + 0.009 × 60 = 0.590. With a water quality storm of 1.2 in, the depth to treat is 0.59 × 1.2 = 0.71 in. The water quality volume is 0.708 / 12 × 5 × 43,560 = 12,850 ft³ (0.295 acre-ft). A facility with an average depth of 3 ft needs 4,283 ft².

Why it matters

The calculator helps civil engineers, land developers, landscape architects, reviewers and students to size the stormwater treatment practices of a site, such as a bioretention area, a pond or a sand filter, and to see the effect of the impervious cover. It gives the target volume in the first step of the stormwater plan.

Good to know

Use the water quality storm and the equation required by the local regulations. Reduce the impervious area and disconnect the downspouts to reduce the volume. Provide a pretreatment, such as a forebay, and an overflow for the larger storms. Check the draw-down time, usually 24 to 48 hours, and the infiltration capacity of the soil.

The SCS curve number calculator gives the runoff of a larger storm, the rain garden calculator sizes a small practice, the rational method calculator gives the peak flow and the detention time calculator gives the time that the water stays in the facility.

Frequently asked questions

What is the water quality volume?

The water quality volume, WQv, is the volume of stormwater runoff that a treatment practice must capture and treat to remove most of the pollution of the site. The first flush of a storm carries the largest share of the pollutants washed from the pavements and the roofs. The regulations define the volume from the runoff of a small storm that is exceeded in only about 10% of the rainfall events.

How is the volume computed?

The simple method gives the runoff coefficient Rv = 0.05 + 0.009 I, where I is the percent of impervious cover. The depth to be treated is Rv multiplied by the rainfall of the water quality storm P, and the volume is this depth times the drainage area. The method is used in many state manuals, such as the Stormwater Management Manual of New York, and in the design of bioretention areas, sand filters, ponds and wetlands.

Why is a small storm used?

Most of the rainfall events are small, and a facility sized for a small storm captures most of the annual runoff volume and of the pollutant load. A larger storm would need very large practices that would be mostly empty. The larger storms are handled by the detention and the conveyance systems, which are sized separately, and the water quality practices are often built in line with a bypass for the high flows.

What are the limits of the calculator?

The calculator gives the volume to treat and an approximate surface for a given depth. It does not size the filter media, the infiltration rate, the draw-down time, the pretreatment or the outlet structure of the practice. The storm and the equations used depend on the local regulations, which can be more demanding. A qualified engineer should design and submit the stormwater management plan.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.