The leaching requirement calculator gives the leaching requirement as a percentage, the gross irrigation depth, the extra water for leaching, the salinity of the drainage water and whether the plan is feasible, from the water and crop salinities.
How the calculation works
- Enter the electrical conductivity of the irrigation water (ECw) in dS/m.
- Enter the tolerable soil salinity (ECe) of the crop for the yield you accept.
- Enter the net irrigation requirement of the crop for the season.
Example
Water of 1.2 dS/m on a crop that tolerates 4 dS/m needs a leaching requirement of 6.4 %. A net requirement of 24 in becomes a gross irrigation of 25.6 in, with 1.6 in of extra water. The drainage water reaches 18.8 dS/m.
Why it matters
The calculator helps farmers, irrigation advisers and students in dry regions, where the irrigation water contains salts, who must plan the extra water to protect the soil and the yield, and who want to decide whether a water source is usable for a given crop.
Good to know
Use the conductivity of the water as measured in the laboratory, and the ECe of the crop for the yield loss that is acceptable, from a salt tolerance table. The formula assumes steady-state conditions, good drainage and no contribution of salts from the soil or from a shallow water table. For high-frequency irrigation and for drip systems, use the specific methods. If ECw is more than 5 times ECe, the formula has no solution and the water cannot be used for this crop without a different management. Always confirm with local guidelines.
Related tools
The crop water need calculator gives the net requirement, the drip irrigation calculator sizes an emitter system, the reference evapotranspiration calculator estimates the water demand of the atmosphere and the available water capacity calculator describes the soil reservoir.