Skip to content
Omnikalc

Doppler resistive and pulsatility index calculator

Enter the peak systolic velocity, the end-diastolic velocity and the time-averaged maximum velocity of a Doppler waveform to get the resistive index (Pourcelot), the pulsatility index (Gosling), the systolic to diastolic ratio and the diastolic fraction.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
cm/s

Value out of range

cm/s

Value out of range

cm/s

Value out of range

Results

Resistive index (Pourcelot)

0.75

Intermediate resistance
Pulsatility index (Gosling)
1.50
Systolic to diastolic ratio
4.00
Diastolic fraction of the peak velocity
25 %

The resistive and pulsatility index calculator gives the resistive index, the pulsatility index, the systolic to diastolic ratio and the diastolic fraction of a Doppler waveform from its peak systolic, end-diastolic and mean velocities.

How the calculation works

  • Enter the peak systolic velocity and the end-diastolic velocity.
  • Enter the time-averaged maximum velocity.
  • Read the resistive index, the pulsatility index and the ratios.

Example

A waveform with a peak systolic velocity of 80 cm/s, an end-diastolic velocity of 20 cm/s and a mean velocity of 40 cm/s has a resistive index of (80 − 20) / 80 = 0.75, a pulsatility index of 60 / 40 = 1.50, and a systolic to diastolic ratio of 4.00. The diastolic velocity is 25 % of the peak.

Why it matters

The calculator helps sonographers, radiologists, obstetricians, nephrologists and students who read Doppler spectra of the kidney, the carotid, the uterine, the umbilical or the limb arteries.

Good to know

The indices are only as good as the measurement of the waveform. Measure on a clean spectrum with several regular cycles, trace the envelope and avoid the beats after an extrasystole. The heart rate, the compliance of the vessel and the compression by the probe all change the indices, and a very high or very low heart rate can mislead. The resistive index is bounded and saturates when diastolic flow is absent, so the pulsatility index is better in that case. Interpret every value with the reference ranges of the organ, the age or the gestational age, and in the clinical context. This page does not diagnose a disease and does not replace the report of a physician.

The Doppler velocity calculator converts a frequency shift into velocity, the cardiac output calculator treats the heart, the mean arterial pressure calculator links pressure and resistance and the aortic valve area calculator uses Doppler velocities.

Frequently asked questions

What do the two indices measure?

Both describe how much the velocity falls between systole and diastole. They reflect the resistance of the vascular bed downstream and the compliance of the vessel, and do not depend on the angle of insonation, since they are ratios of velocities.

How is each index defined?

The resistive index is (PSV − EDV) / PSV and lies between 0 and 1 when diastolic flow is forward. The pulsatility index is (PSV − EDV) / mean velocity and has no upper limit, so it also works when diastolic flow is absent or reversed.

What values are normal?

It depends on the organ. A kidney usually has a resistive index below about 0.70, while the external carotid, the limb arteries and the umbilical artery of a fetus have organ-specific ranges that also change with age or gestation. Always use the reference of the vessel examined.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.