When the mitral valve does not close properly, part of the blood leaks backwards into the left atrium at each heartbeat. Echocardiographers grade how severe this mitral regurgitation is, partly by estimating the size of the leak. The PISA method does this from colour Doppler: it measures the radius of the convergence zone of the flow just before the valve. This calculator turns the PISA radius, the aliasing velocity, the peak jet velocity and the jet VTI into the effective regurgitant orifice area (EROA) and the regurgitant volume.
How the calculation works
- Flow rate at the PISA shell = 2π × r² × Va
- EROA = 2π × r² × Va ÷ Vmax
- Regurgitant volume = EROA × VTI of the regurgitant jet
- Radius in cm, velocities in cm/s, VTI in cm; the EROA is in cm² and the volume in mL
Example
The PISA radius is 8 mm at an aliasing velocity of 40 cm/s, and the regurgitant jet has a peak velocity of 5 m/s and a VTI of 150 cm. The EROA is 2π × 0.8² × 40 ÷ 500 = 0.32 cm², in the moderate range. The regurgitant volume is 0.32 × 150 = 48 mL per beat. The peak flow rate at the shell is 161 mL/s.
Why it matters
The EROA and regurgitant volume help decide whether regurgitation is mild, moderate or severe, which guides follow-up and the timing of surgery or a valve repair. A large leak overloads the left ventricle over time and can lead to heart failure and atrial fibrillation.
Good to know
Measurements are sensitive: since the radius is squared, a 1 mm error on 8 mm changes the EROA by 25%. It is best to shift the baseline of the colour scale to get a clear hemisphere, and to measure at mid-systole. The grading thresholds used here are those for primary mitral regurgitation, and other valves and causes use other cut-offs. This tool is educational.
Related tools
The mitral valve area calculator evaluates stenosis, the cardiac output calculator gives the forward flow, and the Qp:Qs ratio calculator measures shunts with another approach.