Skip to content
Omnikalc

How large is a left-to-right heart shunt?

Enter the oxygen saturations in the aorta, in mixed venous blood, in the pulmonary vein and in the pulmonary artery: get the Qp:Qs ratio and the shunt fraction.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
%

Value out of range

%

Value out of range

%

Value out of range

%

Value out of range

Results

Qp:Qs ratio

1.69

1.5 to 2.0: a moderate left-to-right shunt
Left-to-right shunt fraction
40.7%
Systemic arteriovenous saturation difference
27 points
Pulmonary venoarterial saturation difference
16 points

Some congenital heart defects, such as a hole between the two upper chambers, let oxygen-rich blood flow back to the lungs instead of going to the body. During cardiac catheterization, doctors measure oxygen saturations in different chambers to estimate how large this shunt is. The result is the Qp:Qs ratio, which compares the blood flow through the lungs (Qp) with the flow through the body (Qs). This calculator computes it from four saturations.

How the calculation works

  • Qp:Qs = (systemic arterial saturation − mixed venous saturation) ÷ (pulmonary vein saturation − pulmonary artery saturation)
  • Left-to-right shunt fraction = 1 − 1 ÷ (Qp:Qs)
  • A ratio of 1 means equal flows, with no net shunt
  • Saturations are in percent; the hemoglobin concentration cancels out

Example

Saturations measured at catheterization: aorta 97%, mixed venous 70%, pulmonary vein 98%, pulmonary artery 82%. The ratio is (97 − 70) ÷ (98 − 82) = 27 ÷ 16 = 1.69. The left-to-right shunt fraction is 1 − 1 ÷ 1.69 = 40.7%: more than a third of pulmonary flow is blood that has just come back from the lungs. A ratio between 1.5 and 2.0 is a moderate shunt.

Why it matters

The size of the shunt helps decide whether a defect should be closed, with a device or with surgery. A small shunt may be watched for years, while a large one over-works the right heart and raises the pressure in the lung vessels over time. The ratio is also used to follow the effect of treatment.

Good to know

The calculation assumes a steady state and accurate sampling. A step-up in saturation of more than about 7% between chambers suggests a shunt at that level. Right-to-left shunting, as in cyanotic defects, reduces systemic saturation and needs another interpretation. The decision to treat depends on the full clinical and hemodynamic picture. This tool is for education.

The cardiac output calculator gives the flow, the pulmonary vascular resistance calculator evaluates the lung vessels, and the oxygen delivery calculator relates flow and oxygen content.

Frequently asked questions

What is the Qp:Qs ratio?

The ratio of pulmonary blood flow (Qp) to systemic blood flow (Qs). In a healthy heart the two are equal and the ratio is 1. In a left-to-right shunt, such as an atrial septal defect, extra blood recirculates through the lungs and the ratio exceeds 1.

How is it calculated from saturations?

With the Fick principle, the flows are inversely proportional to the oxygen content differences, so Qp:Qs = (systemic arterial − mixed venous saturation) ÷ (pulmonary vein − pulmonary artery saturation). The hemoglobin cancels out.

What ratio is considered significant?

A ratio of 1.5 or more is generally considered a significant left-to-right shunt, and 2.0 or more a large one. Guidelines for closing defects also consider symptoms, chamber size and pulmonary pressures.

Where is mixed venous blood sampled?

In the pulmonary artery when there is no shunt at that level, or by averaging samples from the superior and inferior vena cava, for example (3 × SVC + 1 × IVC) ÷ 4. The exact method depends on the defect.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.