Skip to content
Omnikalc

Hounsfield unit (CT number) calculator

Enter the linear attenuation coefficient of a tissue and the one of water at the same energy to get the CT number in Hounsfield units, the contrast against a reference tissue and the likely tissue type.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
cm⁻¹

Value out of range

cm⁻¹

Value out of range

HU

Value out of range

Results

CT number

53 HU

Soft tissue range
Contrast against the reference tissue
13 HU
Approximate relative density (water = 1)
1.053
Transmission through 1 cm of the tissue
81.9 %
Half-value layer of the tissue
3.47 cm

The Hounsfield unit calculator gives the CT number of a tissue from its linear attenuation coefficient and the one of water, and compares it with a reference tissue.

How the calculation works

  • Enter the attenuation coefficient of the tissue and of water.
  • Enter the CT number of a reference tissue.
  • Read the CT number, the contrast and the transmission.

Example

A tissue with μ = 0.20 cm⁻¹ and water at 0.19 cm⁻¹ has a CT number of 1000 × (0.20 − 0.19) / 0.19 = 53 HU, in the soft tissue range. Against a reference tissue at 40 HU the contrast is 13 HU. The tissue transmits 81.9 % of the beam through 1 cm and its half-value layer is 3.47 cm.

Why it matters

The calculator helps CT technologists, radiology residents, medical physicists and students who learn how attenuation is turned into gray values, and anyone who wants to link a CT number to physical density.

Good to know

The Hounsfield scale was designed so that the CT number of a tissue stays similar between scanners, but it is not an absolute property. The value changes with the beam energy because the photoelectric effect depends on the atomic number, which is why bone and iodine look different at 80 and 140 kV and why dual energy CT can separate materials. Beam hardening, scatter and the reconstruction kernel also shift the numbers by several units. Use CT numbers as a guide to the type of tissue, not as a definite diagnosis, since many tissues overlap. For lung and fat the relative density is roughly 1 + HU/1000 in the range shown, which is a simplification without the effect of atomic composition.

The CT dose calculator gives the scanner output, the contrast to noise calculator measures visibility, the Beer-Lambert calculator treats attenuation through a thickness and the size specific dose calculator corrects for patient size.

Frequently asked questions

What is a Hounsfield unit?

It is the scale of CT numbers: HU = 1000 × (μ − μwater) / μwater. Water is 0 HU and air is about −1000 HU, which gives a scale that does not depend on the scanner, apart from small calibration differences.

What are the usual values?

Fat is about −100 HU, water 0, blood 40, liver 60, fresh blood clots 50 to 80, contrast filled vessels 200 to 400 and dense bone above 400. Lung is around −800 HU. Values shift with the kVp and the reconstruction.

Which attenuation coefficient should I use?

Use values at the same effective energy for the tissue and the water, for example about 0.19 cm⁻¹ for water around 70 keV. The coefficient of the tissue depends strongly on the energy, in particular for bone and contrast agents.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.