Skip to content
Omnikalc

Proton range calculator (Bragg-Kleeman)

Enter the proton energy, the depth of the target and the relative stopping power of the tissue to get the range in water, the energy needed to reach the target, the range straggling and the water-equivalent depth.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
MeV

Value out of range

cm

Value out of range

Value out of range

Results

Energy needed to reach the target

131.3 MeV

Within the energy range of clinical proton accelerators
Range in water at the chosen energy
15.64 cm
Water-equivalent depth of the target
12.36 cm
Range straggling (standard deviation) at the chosen energy
0.157 cm
Range in tissue at the chosen energy
15.18 cm

The proton range calculator gives the range of protons in water, the energy needed to reach a target depth and the range straggling with the Bragg-Kleeman rule and the relative stopping power of the tissue.

How the calculation works

  • Enter the proton energy.
  • Enter the target depth and the relative stopping power.
  • Read the range, the energy needed and the straggling.

Example

A 150 MeV proton beam has a range of 0.0022 × 150^1.77 = 15.64 cm in water. A target at 12 cm in soft tissue with a stopping power of 1.03 is at a water-equivalent depth of 12.36 cm, and needs 131.3 MeV. The range straggling at 150 MeV is about 0.157 cm.

Why it matters

The calculator helps medical physics students, radiation oncologists, dosimetrists and engineers who learn why protons stop at a precise depth and how the beam energy is selected for a tumor.

Good to know

The Bragg peak is the sharp maximum of the dose at the end of the proton range, and it spares the tissue behind the target, which is the main interest of proton therapy. In practice, a single pristine peak is too narrow, so the beam energy is modulated to create a spread-out Bragg peak that covers the full depth of the tumor. The empirical rule used here is accurate to a few percent for water and gives a first estimate only. Real treatment planning uses CT-based stopping power maps, which carry uncertainties of about 3 percent, and adds safety margins at the distal end. Heterogeneities such as bone, lung and air cavities change the range, and motion changes it further. Use this page for education.

The electron depth rules calculator treats electron beams, the BED calculator compares fractionation, the conformity index calculator evaluates plans and the de Broglie calculator treats particle wavelengths.

Frequently asked questions

What is the Bragg-Kleeman rule?

It is an empirical power law for the range of protons in a material: R = α E^p. In water, with the range in centimeters and the energy in MeV, α is about 0.0022 and p about 1.77, good to within a few percent from 10 to 200 MeV.

What is the relative stopping power?

It is the stopping power of the tissue divided by that of water. Fat is about 0.95, soft tissue about 1.03 to 1.05, lung about 0.2 to 0.3 and bone about 1.5 to 1.9. The water-equivalent depth is the sum of the thicknesses times these ratios.

Why does the range straggle?

Energy loss is a statistical process, so protons of the same energy stop at slightly different depths. The straggling is about 1.2 % of the range, which, with the energy spread of the beam, gives a distal edge a few millimeters wide.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.