The electron beam depth rules calculator gives the depth of the 90 %, 80 % and 50 % doses, the practical range, the lead shield thickness and the energy needed to cover a target from the nominal electron energy.
How the calculation works
- Enter the nominal electron energy in MeV.
- Enter the depth of the distal edge of the target.
- The calculator gives the depths, the range, the lead thickness, the energy needed and the margin.
Example
A 12 MeV beam has a 90 % depth of 12 / 3.2 = 3.75 cm, an 80 % depth of 12 / 2.8 = 4.29 cm, a 50 % depth of 5.15 cm and a practical range of 12 / 2 = 6.00 cm. A target ending at 3 cm needs 3 × 3.2 = 9.6 MeV, so 12 MeV leaves a margin of 2.4 MeV. A lead shield of 6.0 mm stops the beam.
Why it matters
The calculator helps radiation therapy students and dosimetrists who learn the choice of electron energy for superficial tumors, skin cancers and boost fields.
Good to know
The rules apply to broad beams in water at the standard distance and are approximate. The actual depth doses depend on the applicator, the field size, the distance and tissue inhomogeneities such as bone, lung or air cavities. The surface dose is high, between 75 % and 95 %, and rises with energy. Bolus is used to bring the build-up closer to the skin and to flatten the surface. Always use measured data from the machine and the planning system. This page is for education only and is not a substitute for clinical dosimetry.