Skip to content
Omnikalc

Radioiodine activity calculator (Marinelli formula)

Enter the thyroid volume, the target absorbed dose, the 24 hour radioiodine uptake and the effective half-life to get the calculated activity of iodine-131 in megabecquerels and millicuries, and the dose delivered by a fixed activity.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
mL

Value out of range

Gy

Value out of range

%

Value out of range

days

Value out of range

MBq

Value out of range

Results

Calculated activity of iodine-131

250 MBq

An activity in the usual range for treating hyperthyroidism
Calculated activity in millicuries
6.8 mCi
Dose delivered by the fixed activity
222 Gy
Activity per gram of thyroid tissue (uptake not included)
12.5 MBq/g
Activity taken up by the thyroid at 24 hours
150 MBq

The radioiodine activity calculator gives the activity of iodine-131 for a target absorbed dose from the thyroid volume, the 24 hour uptake and the effective half-life with the Marinelli formula, and the dose given by a fixed activity.

How the calculation works

  • Enter the thyroid volume and the target dose.
  • Enter the 24 hour uptake and the effective half-life.
  • Read the activity in MBq and mCi and the dose of a fixed activity.

Example

For a thyroid of 20 mL, a target of 150 Gy, an uptake of 60 % and an effective half-life of 5 days, the activity is 24.99 × 150 × 20 / (60 × 5) = 250 MBq, or 6.8 mCi. A fixed activity of 370 MBq would deliver 370 × 60 × 5 / (24.99 × 20) = 222 Gy.

Why it matters

The calculator helps nuclear medicine students, physicians, physicists and technologists who learn how the radioiodine activity is related to the thyroid size and function, and patients who want to understand the planning.

Good to know

The formula is a simplification: it assumes a uniform uptake, a constant effective half-life, a thyroid mass equal to the volume in milliliters at a density of one, and a short-range beta dose without the gamma contribution. The thyroid volume comes from ultrasound, and an error of 20 percent in the volume gives the same error in the activity. The uptake and the effective half-life are measured with a tracer dose, and they change with the iodine intake, antithyroid drugs and the stage of the disease. Actual practice also includes radiation protection rules for the patient and the family, a pregnancy test, and a follow-up of thyroid function. This page is for education and does not replace the plan prepared by the treating team.

The patient release calculator treats the radiation protection after treatment, the effective half-life calculator combines physical and biological clearance, the MIRD calculator estimates organ dose and the radioactive decay calculator handles decay.

Frequently asked questions

What is the Marinelli formula?

The classic calculation of the activity of iodine-131 is A (MBq) = 24.99 × D (Gy) × V (mL) / (U (%) × Teff (days)). It follows from the energy that the beta particles deposit in the thyroid tissue over the effective life of the iodine in the gland.

Which doses are used?

Calculated-dose approaches use about 100 to 150 Gy for Graves disease, and higher doses of 150 to 250 Gy for toxic nodular goiter, according to the protocol. Many centers use fixed activities instead. The decision is made by the nuclear medicine physician.

Why is the effective half-life limited to 8 days?

The effective half-life cannot exceed the physical half-life of iodine-131, 8.02 days. It is shorter when the iodine turns over quickly in the gland, as in severe hyperthyroidism.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.