The Butler-Volmer equation calculator gives the net current density of an electrode, its anodic and cathodic parts, the linear approximation and the charge-transfer resistance from the overpotential and the exchange current density.
How the calculation works
- Enter the overpotential and the exchange current density.
- Enter the transfer coefficients and the temperature.
- The calculator gives the net current, the two parts, the linear approximation, the resistance and the reverse share.
Example
At 25 °C, F / RT is 38.92 V⁻¹. For an overpotential of 100 mV, an exchange current of 0.1 mA/cm² and α = 0.5 each way, the anodic part is 0.1 × exp(1.946) = 0.7001 mA/cm² and the cathodic part 0.0143 mA/cm². The net current is 0.6858 mA/cm². The charge-transfer resistance is 256.9 Ω·cm², and the linear formula would give 0.3892 mA/cm², which shows its limit.
Why it matters
The calculator helps electrochemistry students, researchers in batteries, sensors and fuel cells, and engineers who model electrodes and interpret impedance spectra.
Good to know
The equation assumes that charge transfer is the only slow step. In real cells, the transport of species to the surface and the resistance of the solution add to it, and the measured curve flattens at the limiting current. The overpotential is the electrode potential minus its equilibrium value, so the Nernst equation gives the reference. For the anodic and cathodic coefficients, a sum of one is common for a single-electron step. Dividing by the real surface area gives a current density per true area. Negative overpotentials give a negative net current, which is a reduction. Keep the exponent below about 40 to avoid numerical overflow in your own calculations.
Related tools
The Tafel equation calculator covers large overpotentials, the Nernst calculator gives equilibrium potentials, the Arrhenius calculator treats temperature effects and the Faraday induction calculator covers electromagnetic induction.