Skip to content
Omnikalc

Chemical feed rate calculator: how much chlorine or coagulant per day?

Enter the flow, the dose, the product strength and its specific gravity to get the pure chemical and product needed per day and the metering pump setting in gallons per hour.

Updated on
Your inputs
MGD

Value out of range

mg/L

Value out of range

% by weight

Value out of range

Value out of range

Results

Pure chemical needed

25.02 lb/day

Product needed
200.2 lb/day
Volume of product per day
20.51 gal/day
Volume of product per hour
0.855 gal/h

How many pounds of chemical does a plant use each day? The chemical feed rate calculator converts the flow of water and the target dose into the pure chemical needed, then, from the strength and the specific gravity of the product, into the product per day and the metering pump setting.

How the calculation works

  • Enter the water flow in million gallons per day (MGD), the target dose of chemical in mg/L, the strength of the product and its specific gravity.
  • The mass of pure chemical is lb/day = flow (MGD) × dose (mg/L) × 8.34, where 8.34 is the weight of a gallon of water in pounds.
  • The mass of product is the pure mass divided by its strength.
  • The volume of product per day and per hour is the mass divided by the density (8.34 × specific gravity) and is the setting of the metering pump.

Example

A plant treats 1.5 MGD and wants a dose of 2 mg/L of chlorine from a 12.5 % sodium hypochlorite solution of specific gravity 1.17. The pure chlorine is 1.5 × 2 × 8.34 = 25.02 lb/day. The product needed is 25.02 / 0.125 = 200.2 lb/day, which is 20.51 gal/day or 0.855 gal/h on the metering pump.

Why it matters

Dosing the right amount of chlorine, coagulant, fluoride or pH adjuster is the daily job of a water treatment operator, and the same formula serves a pool, a well or a cooling tower. A mistake leads to too little disinfection or a waste of chemicals, so a check of the calculation is worth a minute.

Good to know

The calculator gives the dose that is fed, not the residual that is left, because a part of the chemical is used up by the demand of the water. Liquid products are often sold by volume strength (trade percent, grams per liter) and not by weight, and the strength decreases with time and heat, as for hypochlorite. Use the actual strength from the label or the lab, and the specific gravity at the temperature of use. The 8.34 factor is for water at normal temperature.

The detention time calculator gives the contact time in a basin, the dilution calculator prepares a weaker solution from a stronger one, the pool chlorine calculator is the small-scale version, and the water purification calculator covers the treatment steps.

Frequently asked questions

What is the formula for the chemical feed rate?

In US units, the feed rate in pounds per day is flow in MGD times the dose in mg/L times 8.34, the weight in pounds of a gallon of water. It follows because 1 mg/L is 1 part per million by weight, so a million pounds of water carry one pound of chemical per mg/L. It is the basic formula of water treatment operators.

How do I account for the product strength?

A commercial product is not 100 % active. Sodium hypochlorite is sold at 12.5 to 15 % available chlorine, calcium hypochlorite at about 65 %, and liquid alum at about 48 % by weight. Divide the pure mass by the fraction of strength to get the mass of product, then by its density to get the volume that the pump must deliver.

How do I set a metering pump?

The pump setting is the volume of product per hour, in gallons or liters per hour, which this calculator gives. A pump is usually set by stroke length and frequency from its calibration curve, and the real flow is checked with a calibration column. When the flow of water changes, the pump rate must follow it, or the dose changes.

What are typical doses?

For disinfection, a chlorine dose of 2 to 5 mg/L is common, giving a residual of 0.2 to 2 mg/L at the tap after the demand is met. Coagulants, such as alum, are dosed at 10 to 50 mg/L depending on the raw water. Fluoride is dosed at about 0.7 mg/L, and the dose of a polymer is often 0.1 to 2 mg/L.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.