Every distillation column needs a certain number of stages, and there is a hard lower limit. The Fenske equation calculator takes the purity of the distillate, the content of the bottoms and the relative volatility, and gives the minimum number of theoretical stages at total reflux, the separation factor, a rough number of real theoretical stages and the effect of a lower relative volatility.
How the calculation works
- Enter the mole percent of the light component wanted in the distillate and the amount allowed in the bottoms, and the average relative volatility α of the two components.
- The calculator applies the Fenske equation for a column that runs at total reflux, with no product withdrawn: N_min = ln[(xD / (1 − xD)) × ((1 − xB) / xB)] / ln α.
- The result is the minimum number of theoretical stages, including the partial reboiler. No column can do the separation with fewer stages, whatever the reflux.
- As a rule of thumb, the real column needs about twice the minimum number of stages. It also shows how the result changes if the relative volatility is 20 % lower.
Example
A column must make a distillate of 95 mol % of the light component from a bottoms with 5 mol %, for a mixture with a relative volatility of 2.5. The separation factor is (95 / 5) × (95 / 5) = 361. The minimum number of stages is ln(361) / ln(2.5) = 6.43, and a real column would need about 12.9 theoretical stages. If α were 20 % lower, at 2.0, the minimum would rise to 8.5.
Why it matters
The minimum number of stages is the start of every shortcut design of a distillation column, and a quick check on a proposed design. It shows the strong effect of the relative volatility and of the purity: asking for more purity or working with a less volatile pair means many more stages and a taller, more costly column.
Good to know
The equation is for binary mixtures, or for the key components of a multicomponent mixture, with a constant relative volatility along the column and total reflux. The relative volatility varies with the composition and temperature, and for a non-ideal mixture it can vary strongly. The number is the minimum possible, and it is not the number for a real operation. The factor 2 is a rule of thumb.
Related tools
The Raoult’s law calculator gives the vapour pressure of a mixture, the Antoine equation calculator gives the vapour pressure of a pure liquid, the boiling point elevation calculator covers solutions with a non-volatile solute, and the Clausius–Clapeyron calculator links vapour pressure to temperature.