Your inputs
ft

Value out of range

ft

Value out of range

ft/s

Value out of range

°F

Value out of range

Results

Average heat transfer coefficient

1.54 BTU/h·ft²·°F

Heat flux
111.0 BTU/h·ft²
Total heat transfer
666 BTU/h
Average Nusselt number
311.5
Reynolds number at the end of the plate
275,768
Laminar boundary layer over the whole plate

A surface in a moving fluid is cooled or heated by forced convection. The flat plate forced convection calculator finds the average heat transfer coefficient of a flat plate from the fluid, the plate length, the free-stream velocity and the temperature difference. It gives the Reynolds and Nusselt numbers, the heat flux and the total heat transfer.

How the calculation works

  • Choose the fluid (water or air at a chosen temperature) and enter the length, width and free-stream velocity, and the temperature difference between the plate and the fluid.
  • The calculator finds the Reynolds number at the end of the plate, Re = V L / ν.
  • For a laminar boundary layer (Re below 500,000) the average Nusselt number is Nu = 0.664 Re^½ Pr^⅓, and for a mixed layer Nu = (0.037 Re^0.8 − 871) Pr^⅓.
  • The average coefficient is h = Nu k / L, and the heat transfer is h × A × ΔT.

Example

Air at 68 °F flows at 15 ft/s along a plate 3 ft long and 2 ft wide that is 72 °F hotter. The Reynolds number is 275,800, so the boundary layer is laminar. The Nusselt number is 311.5, the average coefficient is 1.54 BTU/h·ft²·°F, the flux is 111 BTU/h·ft², and the total heat is 666 BTU/h.

Why it matters

Flat plate correlations are used as a first model of a heat sink fin, an electronic board in a fan stream, a solar collector in the wind, a wall in an air flow and an aircraft or vehicle panel. The calculator shows the effect of speed and size on the coefficient and the heat.

Good to know

The correlations are for an isothermal, smooth flat plate in a steady, parallel flow with a sharp leading edge, and with properties taken at the film temperature that are fixed here at five temperatures. A rough plate, a non-uniform temperature, a pressure gradient, a high turbulence in the free stream or a high Mach number change the result. Radiation and natural convection are not included.

The Nusselt number calculator covers the dimensionless coefficient, the Prandtl number calculator covers the fluid property, the Reynolds number calculator covers the flow regime, and Newton’s law of cooling calculator uses the coefficient for the cooling of a body.

Frequently asked questions

What is forced convection?

It is the heat transfer to or from a surface in a fluid that is moved by a fan, a pump or the wind, not by buoyancy. The flow thins the thermal boundary layer along the surface, so the coefficient is much higher than in natural convection. It is the basis of the cooling of electronics, the heating of buildings, wind effects on structures and many industrial processes.

Why is the average coefficient larger for a shorter plate?

In a laminar flow, the boundary layer starts thin at the leading edge and grows downstream, so the local coefficient falls as x^−½. The average over a length L is twice the local value at the end, h = 2 h(L), and it varies as L^−½. A short plate has a higher average coefficient than a long one.

What happens when the flow becomes turbulent?

Above a transition Reynolds number of about 500,000 (it varies from 100,000 to 3,000,000 with the roughness and the disturbance), the boundary layer turns turbulent and the coefficient rises sharply. The mixed correlation combines the laminar part at the start and the turbulent part, with the term −871 that accounts for the laminar start.

How does it compare to the pipe correlation?

A plate has an external flow with a free stream, and a pipe has an internal flow where the boundary layers fill the tube. The plate result varies with the length of the plate, and the pipe result with the diameter. For the flow in a duct use the Dittus–Boelter equation, and for a plate in the wind use this calculator.