A hot wall, a radiator or a panel in still air loses heat by natural convection. This natural convection calculator finds the heat transfer coefficient for a vertical plate from its size, the surface temperature and the air temperature, with the Churchill–Chu correlation. It also gives the heat flux, the total heat, the Rayleigh number and the Nusselt number.
How the calculation works
- Enter the height and width of the vertical plate, the surface temperature and the air temperature.
- The calculator takes the properties of air at the film temperature (the average of the two) and finds the Rayleigh number Ra = g β ΔT L³ / (ν α).
- It applies the Churchill–Chu correlation: Nu = [0.825 + 0.387 Ra^(1/6) / (1 + (0.492 / Pr)^(9/16))^(8/27)]², and then h = Nu × k / L.
- The result is the heat transfer coefficient, the heat flux and the total heat from the plate.
Example
A vertical wall panel 3 ft high and 2 ft wide at 140 °F is in still air at 68 °F. The Rayleigh number is 2.39 × 10⁹, the Nusselt number is 160.9, and the coefficient is 0.834 BTU/h·ft²·°F. The heat flux is 60.1 BTU/h·ft², and the total from the panel is 360 BTU/h.
Why it matters
Many heat losses and gains happen with no fan: a hot pipe or an oven wall, a radiator, a window, a transformer or an electronic enclosure. The coefficient for natural convection is the base of the calculation of the surface temperature and the heat loss in all of these cases, and a quick estimate helps to size insulation or heat sinks.
Good to know
The correlation is for a vertical isothermal plate in still air at normal pressure, in laminar and turbulent flow. It does not apply to a horizontal or inclined surface, to an enclosed space, to forced air movement or to other fluids than air, because it uses fixed air properties with a Prandtl number of 0.71. It covers convection only, not radiation, which must be added for a hot surface.
Related tools
The Nusselt number calculator covers the dimensionless heat transfer, the Prandtl number calculator covers the fluid property used here, Newton’s law of cooling calculator uses the coefficient to find the cooling rate, and the heat loss calculator covers building elements.