Skip to content
Omnikalc

Natural convection calculator: heat lost from a hot vertical surface to still air

Enter the size of a vertical plate and the surface and air temperatures to get the Rayleigh and Nusselt numbers, the convection coefficient and the heat transfer.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

°F

Value out of range

°F

Value out of range

Results

Convection heat transfer coefficient

0.834 BTU/h·ft²·°F

Heat flux
60.1 BTU/h·ft²
Total heat transfer
360 BTU/h
Rayleigh number (× 10⁹)
2.386
Transition to turbulence: the Churchill–Chu fit still applies
Nusselt number
160.9

A hot wall, a radiator or a panel in still air loses heat by natural convection. This natural convection calculator finds the heat transfer coefficient for a vertical plate from its size, the surface temperature and the air temperature, with the Churchill–Chu correlation. It also gives the heat flux, the total heat, the Rayleigh number and the Nusselt number.

How the calculation works

  • Enter the height and width of the vertical plate, the surface temperature and the air temperature.
  • The calculator takes the properties of air at the film temperature (the average of the two) and finds the Rayleigh number Ra = g β ΔT L³ / (ν α).
  • It applies the Churchill–Chu correlation: Nu = [0.825 + 0.387 Ra^(1/6) / (1 + (0.492 / Pr)^(9/16))^(8/27)]², and then h = Nu × k / L.
  • The result is the heat transfer coefficient, the heat flux and the total heat from the plate.

Example

A vertical wall panel 3 ft high and 2 ft wide at 140 °F is in still air at 68 °F. The Rayleigh number is 2.39 × 10⁹, the Nusselt number is 160.9, and the coefficient is 0.834 BTU/h·ft²·°F. The heat flux is 60.1 BTU/h·ft², and the total from the panel is 360 BTU/h.

Why it matters

Many heat losses and gains happen with no fan: a hot pipe or an oven wall, a radiator, a window, a transformer or an electronic enclosure. The coefficient for natural convection is the base of the calculation of the surface temperature and the heat loss in all of these cases, and a quick estimate helps to size insulation or heat sinks.

Good to know

The correlation is for a vertical isothermal plate in still air at normal pressure, in laminar and turbulent flow. It does not apply to a horizontal or inclined surface, to an enclosed space, to forced air movement or to other fluids than air, because it uses fixed air properties with a Prandtl number of 0.71. It covers convection only, not radiation, which must be added for a hot surface.

The Nusselt number calculator covers the dimensionless heat transfer, the Prandtl number calculator covers the fluid property used here, Newton’s law of cooling calculator uses the coefficient to find the cooling rate, and the heat loss calculator covers building elements.

Frequently asked questions

What is natural convection?

It is the heat transfer by a fluid that moves only because of density differences caused by temperature, with no fan or pump. Air next to a hot wall warms up, becomes lighter and rises, and cool air replaces it. The flow, and thus the heat transfer, grow with the temperature difference and the size of the surface.

What is the Rayleigh number?

It is the product of the Grashof number (buoyancy over viscosity) and the Prandtl number. It compares the buoyancy forces with the viscous and thermal diffusion that resist the flow. For a vertical plate, the boundary layer is laminar for Ra below about 10⁹, and it becomes turbulent above it.

Why is the film temperature used?

The properties of air change with temperature, and the boundary layer is between the surface and the air. The average of the two temperatures is the standard reference at which the viscosity, the conductivity and the expansion coefficient (β = 1/T for an ideal gas) are taken.

How does the result compare to a typical value?

The coefficient for natural convection of air is small, usually 2 to 25 W/m²·K (0.35 to 4.4 BTU/h·ft²·°F), against 25 to 250 for forced convection of air. In many cases of a hot surface at moderate temperature, radiation exchange adds about as much heat as natural convection, so the total can be twice the value shown.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.