Skip to content
Omnikalc

Superconductor critical field calculator

Choose the metal, the temperature and the applied field to get the critical field at that temperature, the Silsbee current and the margin before superconductivity is lost.

Updated on
Your inputs
K

Value out of range

G

Value out of range

mil

Value out of range

Results

Critical field at the operating temperature

529 G

Silsbee critical current of the wire

67.2 A

Critical temperature Tc
7.19 K
Critical field at 0 K
803 G
State (1 superconducting, 0 normal)
1
Field margin before the transition
329 G
Highest temperature that stays superconducting at the applied field
6.23 K

The superconductor critical field calculator gives the critical temperature, the critical field at 0 K and at the operating temperature, the Silsbee critical current of a wire, the state of the superconductor and the margin before the transition, for six common metals.

How the calculation works

  • Choose the superconducting metal.
  • Enter the operating temperature in kelvin and the applied magnetic field.
  • Enter the wire diameter to get the critical current by the Silsbee rule.

Example

At 4.2 K, the metal has a critical field of 529 G, against 803 G at absolute zero. The applied field is 200 G, so the state is 1 with a margin of 329 G. A wire of 20 mil carries up to 67.2 A before it turns normal, and it stays superconducting up to 6.23 K in that field.

Why it matters

The calculator helps physics and engineering students, laboratory technicians and cryogenics hobbyists who work with superconducting magnets, shields, coils and sensors, and who need a quick check of the temperature, field and current a type I superconductor can sustain.

Good to know

The critical field uses the parabolic law with textbook values of Tc and Hc(0) for pure, annealed elements, and real samples vary with purity, strain and geometry. The Silsbee rule applies to a long straight wire in zero applied field, and combining a transport current with an external field requires a vector sum that this calculator does not do. Type II superconductors have two critical fields and a mixed state with vortices, so treat the results for niobium as a first estimate of the lower critical field only.

The magnetic field of a wire calculator gives the field at the surface of the wire, the solenoid inductance calculator sizes a coil, the London penetration depth calculator describes how far fields enter the surface and the Josephson junction frequency calculator covers another superconducting effect.

Frequently asked questions

What is the critical field of a superconductor?

It is the magnetic field above which superconductivity is destroyed and the metal returns to its normal state. For a type I superconductor, the transition is abrupt and the field expels the flux completely below it (the Meissner effect). The critical field is largest at absolute zero and falls to zero at the critical temperature.

How does the critical field depend on temperature?

It follows the parabolic law Hc(T) = Hc(0) × [1 − (T / Tc)²]. For lead, Hc(0) is about 80 mT (800 gauss) and Tc is 7.19 K, so at 4.2 K, the temperature of liquid helium, the critical field is about 53 mT. Real curves deviate by a few percent from this law.

What is the Silsbee critical current?

The current in a wire creates its own magnetic field at the surface. According to Silsbee’s rule, the wire becomes normal when that field reaches the critical field, which gives Ic = 2π a Hc, where a is the wire radius. The result is in amperes with Hc in amperes per meter, Hc = Bc / μ₀.

Does it apply to niobium and to high-temperature superconductors?

Niobium is a type II superconductor with a lower critical field near 0.2 T, and the upper critical fields of alloys and ceramics are much higher. This calculator uses the thermodynamic critical field and the Silsbee rule, a good model for type I metals and a first estimate for the lower critical field of others.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.