Every valve restricts the flow, and the flow coefficient (Cv) says by how much. Pick a valve that is too small and it can’t pass your flow; pick one far too large and you lose control and spend more. This calculator finds the Cv you need from the flow, the pressure drop and the liquid, converts it to Kv, and checks how much of a given valve’s capacity you would use.
How the calculation works
- Required Cv = flow (gpm) × √(specific gravity ÷ pressure drop in psi)
- Kv = Cv × 0.865 (flow in m³/h at a drop of 1 bar)
- Share of capacity = required Cv ÷ rated Cv of the valve
- Maximum flow = rated Cv × √(pressure drop ÷ specific gravity)
The formulas are for liquids that stay liquid, with turbulent flow and no flashing.
Example
You need 25 gpm of water through a valve with a drop of 5 psi. The required Cv is 25 × √(1 ÷ 5) = 11.18, or a Kv of 9.67. A valve with a Cv of 15 would run at 75 % of its capacity, a good choice for control. It could pass 33.5 gpm at the same drop.
Why it matters
An undersized valve starves a process and causes a large pressure loss; an oversized one works nearly closed, where small movements change the flow a lot and the seat wears. Sizing by Cv before buying avoids both. It also lets you compare valves of different makes and sizes on one scale, since the coefficient is defined at the same conditions.
Good to know
Do the sizing at the flow and drop where the valve will work most of the time, and check the minimum and maximum cases. Viscous fluids, gases, steam and flashing liquids need corrected formulas. The valve’s published Cv is for its fully open position. Piping reducers around the valve change the effective Cv. This tool is for education and is not a substitute for the manufacturer’s sizing data.
Related tools
The pipe flow velocity calculator checks velocity in the line, the pump power calculator estimates the power for a given flow and head, and the Reynolds number calculator tells you if the flow is turbulent.