Skip to content
Omnikalc

Valve Cv calculator: what flow coefficient do you need?

Enter the flow, the pressure drop, the specific gravity and a valve's Cv rating to get the Cv and Kv needed and the share of the valve's capacity used.

Updated on
Your inputs
gpm

Value out of range

psi

Value out of range

Value out of range

Value out of range

Results

Required flow coefficient Cv

11.18

Equivalent Kv (m³/h at 1 bar)
9.67
Share of the valve's capacity used
75%
The valve works in a good range for control
Maximum flow of the valve at this pressure drop
33.5 gpm

Every valve restricts the flow, and the flow coefficient (Cv) says by how much. Pick a valve that is too small and it can’t pass your flow; pick one far too large and you lose control and spend more. This calculator finds the Cv you need from the flow, the pressure drop and the liquid, converts it to Kv, and checks how much of a given valve’s capacity you would use.

How the calculation works

  • Required Cv = flow (gpm) × √(specific gravity ÷ pressure drop in psi)
  • Kv = Cv × 0.865 (flow in m³/h at a drop of 1 bar)
  • Share of capacity = required Cv ÷ rated Cv of the valve
  • Maximum flow = rated Cv × √(pressure drop ÷ specific gravity)

The formulas are for liquids that stay liquid, with turbulent flow and no flashing.

Example

You need 25 gpm of water through a valve with a drop of 5 psi. The required Cv is 25 × √(1 ÷ 5) = 11.18, or a Kv of 9.67. A valve with a Cv of 15 would run at 75 % of its capacity, a good choice for control. It could pass 33.5 gpm at the same drop.

Why it matters

An undersized valve starves a process and causes a large pressure loss; an oversized one works nearly closed, where small movements change the flow a lot and the seat wears. Sizing by Cv before buying avoids both. It also lets you compare valves of different makes and sizes on one scale, since the coefficient is defined at the same conditions.

Good to know

Do the sizing at the flow and drop where the valve will work most of the time, and check the minimum and maximum cases. Viscous fluids, gases, steam and flashing liquids need corrected formulas. The valve’s published Cv is for its fully open position. Piping reducers around the valve change the effective Cv. This tool is for education and is not a substitute for the manufacturer’s sizing data.

The pipe flow velocity calculator checks velocity in the line, the pump power calculator estimates the power for a given flow and head, and the Reynolds number calculator tells you if the flow is turbulent.

Frequently asked questions

What is the Cv of a valve?

Cv is the flow coefficient: the number of US gallons per minute of water at 60 °F that pass through the valve with a pressure drop of 1 psi. A bigger Cv means a valve that passes more flow for the same drop.

What is the difference between Cv and Kv?

Kv is the metric equivalent: cubic meters per hour of water with a drop of 1 bar. Kv = 0.865 × Cv. Both describe the same property in different units.

How do I size a valve?

Compute the Cv needed for your flow, pressure drop and fluid, then choose a valve whose rated Cv is larger. For control valves, the required Cv should fall between about 20 and 80 percent of the rating for stable control.

Does the fluid matter?

Yes. A denser liquid needs more pressure to move the same volume, which the specific gravity captures. For gases and for liquids close to boiling there are other formulas, because the flow can choke or flash.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.