Anchor bolt pullout calculator: tension capacity of a cast-in anchor bolt

Enter the embedment depth, the edge distance, the concrete strength, the bolt size and the steel strength to get the concrete breakout strength, the steel strength and the design tensile capacity of a single anchor.

Updated on
Your inputs
in

Value out of range

in

Value out of range

psi

Value out of range

in

Value out of range

ksi

Value out of range

Results

Design tensile strength of the anchor

14,413 lb

Basic concrete breakout strength Nb
22,308 lb
Projected area ratio ANc / ANco
0.944
Concrete breakout strength Ncb
25,458 lb
Design concrete breakout strength φNcb (φ = 0.70)
17,821 lb
Design steel strength φNsa (φ = 0.75)
14,413 lb
Governing failure mode (1 = concrete, 2 = steel)
2

An anchor bolt in concrete can fail in the steel or by the breakout of a cone of concrete. The anchor bolt pullout calculator follows ACI 318 to give the concrete breakout strength, the steel strength and the design tensile capacity of a single anchor, and tells which mode governs.

How the calculation works

  • Enter the embedment depth hef of the anchor, the distance to the nearest edge of the concrete and the concrete strength f’c.
  • Select the concrete condition: uncracked, which raises the breakout strength by a factor of 1.25 for cast-in anchors, or cracked, which is the conservative case.
  • Enter the diameter of the bolt and the tensile strength of its steel, such as 58 ksi for an F1554 grade 36 rod.
  • The calculator follows ACI 318 chapter 17 for a single anchor in tension: the concrete breakout Ncb = (ANc / ANco) ψed ψc Nb with Nb = 24 √f’c hef^1.5, and the steel strength Nsa = Ase futa.

Example

A cast-in bolt of 3/4 in with hef = 6 in and f’c = 4,000 psi is 8 in from an edge in uncracked concrete. The basic strength is Nb = 24 × √4000 × 6^1.5 = 22,308 lb. The area ratio is (8 + 9) × 18 / 324 = 0.944, the edge factor is 0.967, and the uncracked factor is 1.25, so Ncb = 25,458 lb and φNcb = 17,821 lb. For the steel, Ase = 0.331 in² and φNsa = 14,413 lb. The steel governs at 14,413 lb.

Why it matters

The calculator helps structural engineers, steel erectors, designers and students to size the embedment of anchor bolts for column bases, equipment and railings, and to see how the edge distance and the embedment depth change the capacity. It gives the hand calculation for a first check.

Good to know

Place the anchors far from the edges when possible, since an edge reduces the breakout strength. Use deeper embedment if the concrete governs. For anchors in shear, groups or seismic zones, use the full design procedure of the code. Check the anchor catalog for post-installed anchors, which have their own approved values.

The bolt shear capacity calculator checks the steel in shear, the bolt torque calculator covers tightening, the base plate size calculator sizes the plate that the bolts hold and the footing size calculator sizes the concrete below.

Frequently asked questions

What is concrete breakout?

When an anchor bolt is pulled in tension, the concrete around it can fail by the separation of a cone of concrete, with an angle of about 35° from the axis of the bolt, which is the breakout. The cone is deeper when the bolt is embedded deeper, and the strength rises with the embedment to the power of 1.5, and with the square root of the concrete strength. An edge or another anchor close by cuts the cone and reduces the strength.

What are the other failure modes?

An anchor can also fail by the yield and the rupture of the steel, by the pullout of the head or the hook out of the concrete, by the side-face blowout of a deep anchor near an edge, and by the splitting of the concrete. For a single cast-in headed bolt that is far from the edges, the checks of the steel and of the breakout are the main ones. Anchors with a shear load, or in groups, need other checks.

Why is there a difference between cracked and uncracked concrete?

Concrete cracks under service loads. A crack that passes through the cone reduces the strength of the breakout, so the code gives a lower strength for cracked concrete. The factor of 1.25 for uncracked concrete is allowed for cast-in anchors where the analysis shows that the concrete will not crack at the anchor. If you do not know, use cracked concrete.

What are the limits of this calculator?

It applies to a single headed anchor in tension, with an edge on one side and no other edge nearby. It does not include groups, shear, combined tension and shear, supplementary reinforcement, the pullout of the head or the side-face blowout. The steel area is estimated at 75% of the gross area. The strength reduction factors assume condition B, and the project code and the engineer govern the design.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.