Skip to content
Omnikalc

Base plate size calculator: steel column base plate dimensions and thickness

Enter the factored load, the concrete strength and the column size to get the required plate area, the plate length and width, the governing cantilever, the required thickness and the bearing strength.

Updated on
Your inputs
kips

Value out of range

ksi

Value out of range

Value out of range

in

Value out of range

in

Value out of range

ksi

Value out of range

Results

Plate thickness rounded up to 1/8 in

1.250 in

Required plate area A1
160.9 in²
Plate length N (rounded up to 1 in)
14 in
Plate width B (rounded up to 1 in)
12 in
Governing cantilever l = max(m, n, n’)
3.20 in
Required plate thickness
1.227 in
Design bearing strength φPp
417.7 kips

A steel column base plate spreads the load of the column over the concrete below. The base plate size calculator follows the AISC design method to give the required plate area, the length and width, the governing cantilever, the thickness and the design bearing strength of the plate.

How the calculation works

  • Enter the factored column load Pu, the concrete strength f’c and the confinement factor √(A2/A1), which is 1.0 if the plate covers all the pedestal and up to 2.0 for a large footing.
  • Enter the depth d and the flange width bf of the steel column, and the yield stress Fy of the plate (36 ksi for A36 steel).
  • The calculator sizes the plate area from the bearing strength φ × 0.85 f’c A1 √(A2/A1) with φ = 0.65, then rounds N and B up to whole inches while keeping the plate proportional to the column.
  • It finds the cantilever l = max(m, n, n’) from the design method of the AISC Design Guide 1, and the thickness t = l √(2 Pu / (0.9 Fy B N)), rounded up to 1/8 in.

Example

A W8×31 column (d = 8 in, bf = 8 in) carries Pu = 400 kips on 3 ksi concrete with √(A2/A1) = 1.5, with a plate of Fy = 36 ksi. The required area is A1 = 400 / (0.65 × 0.85 × 3 × 1.5) = 160.9 in². With Δ = 0.5 (0.95 × 8 − 0.8 × 8) = 0.6 in, N = √160.9 + 0.6 = 13.3, rounded up to 14 in, and B = 160.9 / 14 = 11.5, rounded up to 12 in. The cantilevers are m = 3.2 in, n = 2.8 in and n’ = 2.0 in, so l = 3.2 in. The thickness is t = 3.2 × √(800 / (0.9 × 36 × 12 × 14)) = 1.227 in, which gives a 1.25 in plate with a bearing strength of 417.7 kips.

Why it matters

The calculator helps structural engineering students, designers and steel detailers to size a base plate in a few seconds, to see how the concrete strength and the confinement change the area, and to compare the thickness for different plate steels. It gives a preliminary size before a full connection design.

Good to know

Round the dimensions up to practical values and check that the plate covers the anchor rods, with a margin for the edge distance. Use the real support area to compute √(A2/A1). Remember that a thicker plate uses more steel: sometimes a larger plate with a thinner thickness costs less.

The bolt shear capacity calculator checks the anchor rods, the footing size calculator sizes the concrete footing, the flagpole footing calculator covers an embedded post and the Euler buckling calculator gives the strength of the column itself.

Frequently asked questions

How is a column base plate sized?

First, the area A1 is found from the bearing strength of the concrete: φPp = φ × 0.85 f’c A1 √(A2/A1), with φ = 0.65 and a limit of 1.7 f’c A1. Then the length N and the width B are chosen so that the plate extends beyond the column section by a small margin. Finally, the thickness is found from the bending of the plate in the cantilevers beyond the column, using the factored bearing pressure.

What are m, n and n’?

The cantilevers are measured from the edge of the area that the column actually loads. The value m is the distance in the direction of the depth, from the plate edge to 0.95 d. The value n is the distance in the direction of the width, from the plate edge to 0.8 bf. The value n’ = √(d bf) / 4 covers the case where the plate bends between the flanges. The largest of these three, taken here with a factor λ = 1, governs the thickness.

What is the confinement factor √(A2/A1)?

A2 is the area of the concrete support that is geometrically similar to the plate and concentric with it. The surrounding concrete confines the loaded area, which raises the bearing strength by the factor √(A2/A1), up to 2. For a plate on a footing or a pedestal that is much larger than the plate, it is common to take 1.5 to 2. If you do not know the support, use 1.0 for a conservative result.

What does this calculator not include?

It covers a concentrically loaded plate with a bearing check only. It does not include moments, uplift or shear, the design of the anchor rods, the weld to the column, the grout, the bearing under a very small column or the check of the pedestal. A licensed engineer must design the connection, according to the code and to the Design Guide 1.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.