The bollard vehicle impact calculator gives the kinetic energy of the vehicle, the equivalent static force, the bending moment at the ground and the plastic section modulus required for a steel bollard, from the weight and the speed of the vehicle, the stopping distance and the strength of the steel.
How the calculation works
- Enter the weight of the vehicle and its speed at the impact.
- Enter the stopping distance, the height of the impact above the ground and the yield strength of the steel.
- The calculator finds the kinetic energy, the equivalent static force, the bending moment and the plastic section modulus that the bollard needs.
Example
A pickup of 5,000 lb hits a bollard at 30 mph, that is 44 ft/s. Its energy is 0.5 × (5,000 / 32.174) × 44² = 150.4 kip·ft. If the vehicle stops in 1.5 ft, the equivalent force is 150.4 / 1.5 = 100.3 kip. At an impact height of 2.25 ft, the moment at the ground is 225.6 kip·ft. With steel of 36 ksi and a factor of 0.9, the plastic section modulus must be at least 83.6 in³.
Why it matters
The calculator helps site designers, facility managers, contractors and students to compare the energy of different vehicles and speeds, to see why a bollard in a parking lot needs less than a bollard beside a loading road, and to check the size of a pipe before they ask for a rated product.
Good to know
Choose the design vehicle and the speed from the site: a parking lot, a loading dock and a main road are not the same. Make the stopping distance realistic, because a short distance gives a very large force. Place the bollards so that the vehicle cannot gain speed before them, check the underground pipes and cables before the digging, and prefer a rated and certified product when the risk is high.
Related tools
The crash force calculator gives the force of a stop over a distance, the falling weight impact calculator gives the energy of a drop, the kinetic energy calculator gives the energy of a moving mass and the base plate size calculator sizes the plate of a steel post.