The steel block shear calculator gives the net areas, the block shear rupture strength of the AISC 360 and the demand to capacity ratio of a plate or angle with a line of bolts, from the thickness, the bolt layout, the edge distances and the steel grade.
How the calculation works
- Enter the thickness of the plate, the bolt diameter, the number of bolts, their spacing and the two edge distances.
- Enter Fy and Fu, choose the tension stress on the block and enter the factored load.
- The calculator gives the net areas, the block shear strength of the AISC 360 and the demand to capacity ratio.
Example
A plate 0.375 in thick with 4 bolts of 3/4 in at 3 in spacing, an end distance of 1.5 in and an edge distance of 1.5 in (A36 steel, Fy = 36 ksi, Fu = 58 ksi) has a hole of 0.875 in. The net shear area is 0.375 × 7.4375 = 2.79 in² and the net tension area is 0.375 × 1.0625 = 0.40 in². Shear yielding with tension rupture gives 108.2 kips, lower than the 120.2 kips of shear rupture, so Rn = 108.2 kips and φRn = 0.75 × 108.2 = 81.1 kips. For a factored load of 60 kips the ratio is 0.74.
Why it matters
The calculator helps structural engineers, steel detailers, fabricators and students to check the block shear of a gusset plate, a coped beam or an angle in a few seconds, and to see how much the edge distance or the number of bolts changes the strength.
Good to know
Check the block shear when the edge distance is short, when the beam is coped or when the plate is thin compared with the load, since these are the cases where it controls. Use the real hole size of the shop, and the actual Fy and Fu of the mill report if you know them. Remember that the strength grows with the length of the shear plane, so a wider spacing or one more bolt is the quickest way to add capacity, but more edge distance on the tension side adds less.
Related tools
The bolt shear capacity calculator checks the shear and the bearing of the bolts, the Whitmore gusset width calculator gives the width of the stress zone, the steel tension member calculator checks the member and the slip-critical bolt capacity calculator checks a friction connection.