Skip to content
Omnikalc

Slip-critical bolt calculator: slip resistance of a high strength bolted connection

Choose the bolt size, the surface class, the hole type, the fillers and the number of bolts and slip planes, and enter the factored shear to get the slip resistance per bolt, the design resistance of the connection and the ratio.

Updated on
Your inputs

Value out of range

kips

Value out of range

Results

Design slip resistance of the connection

79.3 kips

Slip resistance per bolt Rn
13.22 kips
Design slip resistance per bolt (φRn)
13.22 kips
Demand to capacity ratio
0.76
The connection resists the slip under the factored load

The slip-critical bolt calculator gives the slip resistance of one bolt, the design slip resistance with φ, the resistance of the connection and the demand to capacity ratio of a pretensioned high strength bolted connection by AISC 360 section J3.8.

How the calculation works

  • Choose the bolt diameter, which gives the minimum pretension, the class of the faying surface and the type of hole.
  • Choose the number of fillers and the number of slip planes, and enter the number of bolts and the factored shear on the connection.
  • The calculator finds the slip resistance of one bolt, the design slip resistance with φ, the resistance of the whole connection and the demand to capacity ratio.

Example

A slip-critical connection has 6 bolts of 7/8 in (pretension 39 kips) on a Class A surface (μ = 0.30), with standard holes, no filler and a single slip plane. The slip resistance of one bolt is 0.30 × 1.13 × 1.0 × 39 × 1 = 13.22 kips, and φ = 1.00 gives 13.22 kips. The connection resists 6 × 13.22 = 79.3 kips, so a factored shear of 60 kips gives a ratio of 0.76.

Why it matters

The calculator helps steel designers, detailers, fabricators and students to check or size a slip-critical connection, to compare the surface classes, and to see how the bolt size, the fillers and the type of hole change the number of bolts needed.

Good to know

Make sure the faying surfaces are prepared and kept free of paint that is not rated for the class, and that the bolts are pretensioned by the turn-of-nut method or with direct tension indicators. Check the connection also for bearing, tearout and block shear.

The bolt shear capacity calculator checks the bearing type of connection, the bolt torque calculator gives the tightening torque, the bolt joint stiffness calculator shows the load in the bolt and the eccentric bolt group calculator checks the load on the bolts of a group.

Frequently asked questions

What is a slip-critical connection?

A slip-critical connection uses high strength bolts that are tightened to a minimum pretension, so that the shear is carried by the friction between the plates and not by the bearing of the bolts on the holes. It is required where a slip would be harmful, for example in connections with fatigue, with load reversal, with oversized holes or slotted holes parallel to the load, and for the serviceability if the designer wants it.

How is the slip resistance found?

AISC 360 section J3.8 gives the nominal slip resistance of a bolt as Rn = μ Du hf Tb ns, where μ is the mean slip coefficient of the faying surface, Du = 1.13 is the ratio of the mean pretension to the specified minimum, hf is the filler factor, Tb is the minimum pretension of the bolt and ns the number of slip planes. For the design, Rn is multiplied by φ, which is 1.00 for standard holes and 0.85 or 0.70 for the larger holes.

What are the Class A and Class B surfaces?

Class A surfaces are unpainted clean mill scale, or coated with a Class A paint, with μ = 0.30. Class B surfaces are blast-cleaned steel without a coating or with a Class B coating, and a galvanized surface roughened by hand wire brushing, with μ = 0.50. The surfaces must be free of oil, grease and loose rust. The type of surface strongly changes the number of bolts needed.

What are the limits of the calculator?

The calculator gives the slip resistance only. It does not include the bolts in combined shear and tension, which reduce the slip resistance, the bearing and tearout checks, the block shear of the plates, the long connections, the A490 bolts with other pretension values or the fatigue. The connection must also resist the load by bearing in case of slip, and it must be made by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.