The slip-critical bolt calculator gives the slip resistance of one bolt, the design slip resistance with φ, the resistance of the connection and the demand to capacity ratio of a pretensioned high strength bolted connection by AISC 360 section J3.8.
How the calculation works
- Choose the bolt diameter, which gives the minimum pretension, the class of the faying surface and the type of hole.
- Choose the number of fillers and the number of slip planes, and enter the number of bolts and the factored shear on the connection.
- The calculator finds the slip resistance of one bolt, the design slip resistance with φ, the resistance of the whole connection and the demand to capacity ratio.
Example
A slip-critical connection has 6 bolts of 7/8 in (pretension 39 kips) on a Class A surface (μ = 0.30), with standard holes, no filler and a single slip plane. The slip resistance of one bolt is 0.30 × 1.13 × 1.0 × 39 × 1 = 13.22 kips, and φ = 1.00 gives 13.22 kips. The connection resists 6 × 13.22 = 79.3 kips, so a factored shear of 60 kips gives a ratio of 0.76.
Why it matters
The calculator helps steel designers, detailers, fabricators and students to check or size a slip-critical connection, to compare the surface classes, and to see how the bolt size, the fillers and the type of hole change the number of bolts needed.
Good to know
Make sure the faying surfaces are prepared and kept free of paint that is not rated for the class, and that the bolts are pretensioned by the turn-of-nut method or with direct tension indicators. Check the connection also for bearing, tearout and block shear.
Related tools
The bolt shear capacity calculator checks the bearing type of connection, the bolt torque calculator gives the tightening torque, the bolt joint stiffness calculator shows the load in the bolt and the eccentric bolt group calculator checks the load on the bolts of a group.