An air receiver is a tank that stores compressed air for the peaks of demand. The compressed air receiver calculator gives the volume needed to supply a peak of known flow and duration while the pressure drops between the cut-out and cut-in pressures of the compressor, with the rule-of-thumb size.
How the calculation works
- Enter the peak air demand in standard cubic feet per minute (scfm) and the duration of the peak in seconds.
- Enter the cut-out pressure (upper) and the cut-in pressure (lower) of the compressor, in psig.
- The calculator gives the receiver volume that supplies the peak without the compressor: V = t × C × Pa / (P1 − P2), with Pa = 14.7 psi.
- It compares the result with the rule of thumb of 3 gallons per scfm and gives the recommended size, the larger of the two.
Example
A machine needs 60 scfm for 60 s, and the compressor cuts out at 125 psig and cuts in at 100 psig. The receiver volume is 1 min × 60 scfm × 14.7 / 25 = 35.3 ft³, which is 264 gal. The rule of thumb gives 3 × 60 = 180 gal, so the recommended size is 264 gal, and a standard 300-gallon receiver would do.
Why it matters
The calculator helps workshop owners, plant engineers, installers and students to size or to check an air receiver, to understand the effect of the pressure band on the tank size and to choose a standard tank. A good size saves electricity by reducing the starts and the pressure losses.
Good to know
The calculator assumes an isothermal expansion of the air in the tank, a constant demand during the peak and that the compressor does not supply air during the peak, which is on the safe side. It does not include the pressure drop in the pipes and the dryers, the temperature changes or the compressor capacity control. Real tanks come in standard sizes, and they must follow the pressure vessel rules of your region.
Related tools
The compression ratio calculator gives the ratio of a compressor, the gas compressibility factor calculator corrects the volume of real gases, the fan affinity laws calculator covers fans and blowers, and the pump power calculator covers the energy of liquid pumps.