Skip to content
Omnikalc

Deck ledger lag screw spacing and load calculator

Enter the span of the deck joists, the design load, the length of the ledger and the allowable load of a lag screw to get the spacing, the load per fastener and the number of lag screws.

Updated on
Your inputs
ft

Value out of range

psf

Value out of range

ft

Value out of range

lb

Value out of range

Results

Maximum spacing of the lag screws

23 in

Number of lag screws

9

Load on the ledger per foot
200 lb/ft
Load carried by each lag screw
383 lb
Ratio to the allowable load
0.96
Each lag screw carries less than its allowable load

The deck ledger lag screw calculator gives the load on the ledger, the maximum spacing of the lag screws from the span of the joists, the load carried by each lag screw, the number of lag screws and the ratio to the allowable load.

How the calculation works

  • Enter the span of the deck joists, the design load and the length of the ledger.
  • Enter the allowable lateral load of one lag screw from the manufacturer or the code.
  • The calculator finds the load on the ledger, the maximum spacing, the load per lag screw, the number of lag screws and the ratio to the allowable load.

Example

A deck with joists spanning 8 ft and a design load of 50 psf puts 50 × 8 / 2 = 200 lb/ft on the ledger. The code table gives a maximum spacing of 23 in for 1/2 in lag screws, so each lag screw carries 200 × 23 / 12 = 383 lb, which is 0.96 of an allowable load of 400 lb. A ledger of 16 ft needs 16 × 12 / 23 = 8.3, rounded up to 9 lag screws.

Why it matters

The calculator helps deck builders, carpenters, homeowners, inspectors and designers to find the fastener schedule of a deck ledger from the code table, to check the load that each lag screw carries and to count the fasteners to buy before the work starts.

Good to know

Fasten the ledger to the band joist of the house, never to the siding or to a brick veneer, and use a 1/2 in lag screw or bolt with washers, hot-dip galvanized or stainless. Predrill the holes, stagger the fasteners, keep the distances from the edges and flash the top of the ledger. Add lateral load connectors to the joists as required by your local code, because the lag screws are not designed to resist the pull of the deck.

The lag screw withdrawal calculator gives the pull-out capacity of a lag screw, the floor joists calculator sizes the joists of a floor, the decking calculator gives the quantity of boards for a deck and the wood beam span calculator gives the span of a wood beam.

Frequently asked questions

What is the load on the ledger?

A deck ledger is bolted to the house and carries the end reaction of the deck joists. For joists on a simple span, half of the load of the joist goes to the ledger, so the load per foot of ledger is the design load times half the span. The usual design load of a residential deck is 40 psf of live load plus 10 psf of dead load, or 50 psf in total.

Where does the spacing come from?

The table of the International Residential Code gives the maximum spacing of the fasteners from the span of the joists, for a 1/2 in lag screw or bolt in a ledger of solid lumber against a rim board of 1 1/2 in. The spacing goes from 30 in for a span of 6 ft to 10 in for a span of 18 ft. The calculator reads the table and checks that the load per fastener stays under the allowable load you enter.

How many rows of lag screws are needed?

The spacing of the table is for two rows of fasteners placed in a staggered pattern, with the edge and end distances required by the code, at least 3/4 in from the edges and 2 in from the top and the bottom of the ledger. The number given by the calculator is the number of positions along the ledger, so count one lag screw per position in each row according to the detail of your plan.

What are the limits of the calculator?

The calculator applies to a ledger fastened to a solid rim board or to a wood-framed wall with a 1/2 in lag screw or bolt. It does not apply to a brick veneer, to a cantilever, to an engineered rim board, to a deck that is not attached, or to a ledger that carries a large point load. Flashing is required above the ledger, and many jurisdictions also require lateral hold-down connectors.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.