The differential leveling calculator gives the misclosure of a level loop, the allowable misclosure for the order of the survey, the ratio between the two and the correction at each setup, from the sums of the backsights and foresights, the length of the loop and the number of setups.
How the calculation works
- Enter the sum of the backsights and the sum of the foresights of a closed level loop.
- Enter the length of the loop, the number of setups and the order of the survey.
- The calculator finds the misclosure, the allowable misclosure, the ratio and the correction at each setup.
Example
A closed loop of 2.5 mi with 18 setups has backsights that add up to 214.386 ft and foresights of 214.351 ft, so the misclosure is +0.035 ft. For a third-order survey the allowable misclosure is 12 mm × √(2.5 × 1.609 km) = 24.07 mm, that is 0.079 ft. The ratio is 0.44, so the loop is accepted, and each setup is corrected by −0.035 / 18 = −0.0019 ft.
Why it matters
The calculator helps surveyors, construction engineers, site managers, students and inspectors to check a level run before they use the heights, to see if the loop must be repeated, and to adjust the heights of the benchmarks and the temporary points of a site.
Good to know
Keep the lengths of the backsights and foresights about equal at each setup, so that the curvature and the refraction cancel. Read the rod twice or use two scales, hold it plumb with a level bubble, and close the loop on the same day when you can. If the ratio is over 1, look for a reading or an arithmetic error before you repeat the work, and never force the closure by adjusting a single point.
Related tools
The grade stake cut and fill calculator gives the cut or fill at a stake from a rod reading, the vertical curve calculator gives the heights on a road profile, the horizontal curve calculator gives the layout of a road curve and the earthwork swell and shrink calculator converts the volumes of soil.