Skip to content
Omnikalc

Differential leveling misclosure and allowable error calculator

Enter the sums of the backsights and foresights, the length of the loop, the number of setups and the order of the survey to get the misclosure, the allowable error and the correction.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

mi

Value out of range

Value out of range

Results

Ratio to the allowable misclosure

0.44

Within the allowable error: distribute the correction
Misclosure of the loop
0.035 ft
Allowable misclosure
0.079 ft
Correction at each setup
-0.0019 ft

The differential leveling calculator gives the misclosure of a level loop, the allowable misclosure for the order of the survey, the ratio between the two and the correction at each setup, from the sums of the backsights and foresights, the length of the loop and the number of setups.

How the calculation works

  • Enter the sum of the backsights and the sum of the foresights of a closed level loop.
  • Enter the length of the loop, the number of setups and the order of the survey.
  • The calculator finds the misclosure, the allowable misclosure, the ratio and the correction at each setup.

Example

A closed loop of 2.5 mi with 18 setups has backsights that add up to 214.386 ft and foresights of 214.351 ft, so the misclosure is +0.035 ft. For a third-order survey the allowable misclosure is 12 mm × √(2.5 × 1.609 km) = 24.07 mm, that is 0.079 ft. The ratio is 0.44, so the loop is accepted, and each setup is corrected by −0.035 / 18 = −0.0019 ft.

Why it matters

The calculator helps surveyors, construction engineers, site managers, students and inspectors to check a level run before they use the heights, to see if the loop must be repeated, and to adjust the heights of the benchmarks and the temporary points of a site.

Good to know

Keep the lengths of the backsights and foresights about equal at each setup, so that the curvature and the refraction cancel. Read the rod twice or use two scales, hold it plumb with a level bubble, and close the loop on the same day when you can. If the ratio is over 1, look for a reading or an arithmetic error before you repeat the work, and never force the closure by adjusting a single point.

The grade stake cut and fill calculator gives the cut or fill at a stake from a rod reading, the vertical curve calculator gives the heights on a road profile, the horizontal curve calculator gives the layout of a road curve and the earthwork swell and shrink calculator converts the volumes of soil.

Frequently asked questions

What is the misclosure?

In a closed level loop the surveyor returns to the starting point or to a point of known height. The sum of the backsights minus the sum of the foresights must equal the difference of height between the first and last points, which is zero for a closed loop. The difference that remains is the misclosure, and it comes from the errors of the readings, of the instrument and of the rod.

How is the allowable error found?

Leveling standards give the allowable misclosure as a constant times the square root of the length of the loop in kilometers. The constant is 4 mm for first order, 6 and 8 mm for the two classes of second order, and 12 mm for third order. A longer loop is allowed a larger error because it has more setups, but the error grows only with the square root of the length.

How is the correction distributed?

If the misclosure is within the limit, the correction is spread over the setups, or over the distance, with the opposite sign. The calculator gives the correction for each setup. The adjusted heights of the intermediate points are computed by adding the cumulative corrections to the raw heights, and the last point then agrees with its known height.

What are the limits of the calculator?

The calculator handles a closed loop between points of known height. It does not include the curvature of the earth and the refraction, which cancel when the sights are balanced, the collimation of the instrument, the weighting of several loops or the least squares adjustment. For a network, use the adjustment software.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.