Skip to content
Omnikalc

Energy use intensity calculator: how much energy does your building use per square foot?

Enter the yearly electricity and gas use, the floor area and the prices to get the energy use intensity in kBtu per square foot and kWh per square meter, and the annual energy cost.

Updated on
Your inputs
kWh

Value out of range

therms

Value out of range

ft²

Value out of range

$

Value out of range

$

Value out of range

Results

Energy use intensity (EUI)

40.4 kBtu/ft²/yr

Typical of existing buildings

Annual energy cost

$2,310

Total site energy
80,826 kBtu
EUI in kWh per square meter
127 kWh/m²/yr
Cost per square foot
$1.16

A bigger house uses more energy, so the bill alone does not say whether a building is efficient. The energy use intensity, or EUI, divides the energy used in a year by the floor area. This energy use intensity calculator takes the electricity, the natural gas, the floor area and the prices to give the EUI in kBtu per square foot, the value in kWh per square meter and the annual energy cost.

How the calculation works

  • Total site energy = electricity in kWh × 3.412 + natural gas in therms × 100, in kBtu (thousand British thermal units).
  • EUI = total site energy ÷ floor area, in kBtu per square foot per year.
  • EUI in kWh per square meter = EUI × 3.15459, the unit used in most of the world.
  • Annual cost = kWh × electricity price + therms × gas price, and cost per square foot = annual cost ÷ floor area.

Example

A house of 2,000 ft² uses 10,500 kWh of electricity and 450 therms of gas a year. Electricity is 10,500 × 3.412 = 35,826 kBtu and gas is 45,000 kBtu, a total of 80,826 kBtu. The EUI is 80,826 ÷ 2,000 = 40.4 kBtu/ft²/yr, or 127 kWh/m²/yr. At $0.16 per kWh and $1.40 per therm the energy bill is $2,310 a year.

Why it matters

The EUI is the standard yardstick for comparing buildings, setting efficiency targets and judging whether a retrofit paid off. Energy Star and building performance standards use it, buyers use it to compare two houses, and a drop of 10 kBtu/ft² on a large building is a large saving.

Good to know

Use a full year of bills so that heating and cooling seasons are included, and compare buildings of the same type in a similar climate. Weather changes the result: a cold winter raises it with no change in the building. Home heating oil, propane and wood are not included here, so add them as kWh if you use them. The scale here is for homes, since offices, schools, restaurants and labs have very different typical values. A low EUI can also mean part of the building is unused.

The heating degree days calculator measures how cold a season was, the heat loss calculator shows where the heat escapes and the room area calculator gives the floor area to divide by.

Frequently asked questions

What is energy use intensity?

It is the energy a building uses in a year divided by its floor area. It lets you compare buildings of different sizes and track one building over time.

What is a good EUI?

For homes, a site EUI below about 35 kBtu/ft²/yr is efficient and a typical existing house uses 40 to 60. Offices, schools and hospitals have their own benchmarks, and hospitals and labs are far higher.

What is the difference between site and source EUI?

Site EUI counts the energy that reaches the building, as on your bills. Source EUI adds the losses of producing and delivering it, so electricity counts for about three times its site value.

How do I convert kBtu to kWh?

One kBtu is 0.293 kWh, and one kWh is 3.412 kBtu. One therm is 100 kBtu, or 29.3 kWh. A kBtu per square foot is 3.155 kWh per square meter.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.