Epoxy crack injection quantity calculator

Enter the length, the width and the depth of the crack, the port spacing and an allowance to get the volume of the crack, the epoxy to order, the ports and the cartridges.

Updated on
Your inputs
ft

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

%

Value out of range

Results

Epoxy to order, with the allowance

115.2 in³

Volume of the crack
76.8 in³
Epoxy in gallons
0.50 gal
Number of injection ports
61
Cartridges of 10 fl oz
7

The epoxy crack injection calculator gives the volume of a crack, the epoxy to order with an allowance, the number of injection ports and the number of cartridges, from the length, the width and the depth of the crack and the spacing of the ports.

How the calculation works

  • Enter the length, the average width and the depth of the crack.
  • Enter the spacing of the ports and the allowance for voids, waste and the surface seal.
  • The calculator finds the volume of the crack, the epoxy to order, the number of ports and the number of cartridges.

Example

A crack of 40 ft with an average width of 0.02 in. through a wall 8 in. thick has a volume of 40 × 12 × 0.02 × 8 = 76.8 in³. With an allowance of 50 percent for voids, waste and the surface seal, the job needs 115.2 in³, that is 0.50 gal of epoxy. Ports at 8 in. make 480 / 8 + 1 = 61 ports, and 115.2 / 18.05 = 6.4 rounds up to 7 cartridges of 10 fl oz.

Why it matters

The calculator helps concrete repair contractors, structural engineers, inspectors and facility managers to estimate the epoxy for a cracked wall, slab or beam, to order the ports and the cartridges, and to price a repair before they start.

Good to know

Measure the width of the crack every 1 or 2 ft and use the average, and add the allowance for the narrow cracks, since a thin crack can take more resin than the calculation shows because of the branches. Inject at a low pressure, between 15 and 40 psi, starting from the bottom of a vertical crack. Order a few more cartridges than the count, and keep the work area above 40 °F.

The concrete crack width calculator gives the width of the cracks of a reinforced member, the adhesive anchor epoxy volume calculator gives the epoxy for anchors, the pavement crack sealing material calculator gives the sealant for a pavement and the epoxy resin calculator gives the resin and the hardener for a mix.

Frequently asked questions

What cracks can be injected with epoxy?

Epoxy injection restores the strength and the monolithic action of a structural crack in a concrete member, with a width from about 0.002 in. to 0.25 in. It is not meant for cracks that are still moving, which need a flexible sealant or polyurethane, and the cause of the crack must be found and stopped first. The concrete must be sound on both sides of the crack and the crack must be clean and dry.

How is the volume computed?

The volume is the length times the average width times the depth of the crack, with the depth equal to the thickness of the member for a crack that goes through. The width varies along the crack, so measure it at several points and use the average, and the crack is often wider at the surface. The allowance covers the narrow ends of the crack, the voids around it, the surface paste and the epoxy left in the mixer and in the hoses.

How are the ports placed?

Injection ports are fixed on the surface along the crack, at a spacing close to the thickness of the member, and the surface of the crack between the ports is sealed with a paste. The epoxy is pumped at low pressure from the lowest port, and the next port is capped when the epoxy appears in it. The calculator counts one port at each end and one at every spacing between them.

What does the calculator leave out?

The calculator does not consider the type of resin, the viscosity, the pot life, the temperature of the concrete, the pump, the grinding of the surface, the drilling of ports or the cleaning. Check the technical data sheet of the product for the coverage and the application, and follow the procedure of ACI 224.1R and ASTM C881 for the epoxy. Test the result with cores when the specification asks for it.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.