Skip to content
Omnikalc

Escalator passenger capacity calculator: persons per hour and units needed

Enter the speed, the step depth, the persons per step, the utilization, the travel and the peak demand to get the capacity, the travel time, the rise and the number of escalators.

Updated on
Your inputs
ft/min

Value out of range

in

Value out of range

Value out of range

Value out of range

ft

Value out of range

persons/h

Value out of range

Results

Escalators needed

2

Steps passing per minute
75.0 steps/min
Theoretical capacity
6,750 persons/h
Practical capacity
5,400 persons/h
Vertical rise
15.0 ft
Travel time
18.0 s

The escalator passenger capacity calculator gives the steps per minute, the theoretical capacity, the practical capacity, the vertical rise, the travel time and the number of escalators needed, from the speed, the step depth, the persons per step and the peak demand.

How the calculation works

  • Enter the speed, the depth of a step, the persons per step and the utilization factor.
  • Enter the length of travel, the angle of the incline and the peak demand of passengers.
  • The calculator finds the theoretical and practical capacities, the rise, the travel time and the number of escalators.

Example

An escalator runs at 100 ft/min with steps 16 in deep, so 75 steps pass per minute. With 1.5 persons per step, the theoretical capacity is 75 × 60 × 1.5 = 6,750 persons/h, and with a utilization of 0.80 the practical capacity is 5,400 persons/h. A travel of 30 ft at a 30 degree incline takes 18.0 s and rises 15.0 ft. For a peak demand of 8,000 persons/h, 2 escalators are needed.

Why it matters

The calculator helps architects, building designers, transport planners and students to size the vertical circulation of a mall, a station or an airport, to compare the speeds and the widths of the escalators, and to check that the exits can handle the flow of passengers.

Good to know

Make sure that the space at the top and at the bottom of the escalator is large enough for the queue, and that the passengers can leave the flow quickly. Add a margin on the number of escalators for the peak flows, and keep a clear path to the stairs and to the elevators for the persons who cannot use the escalator.

The occupant load and egress width calculator gives the exits of a building, the stair calculator plans the steps of a stair, the stairwell pressurization airflow calculator sizes the smoke control of a stairwell and the home elevator cost calculator estimates the cost of a small elevator.

Frequently asked questions

What is the capacity of an escalator?

The theoretical capacity is the number of persons that the escalator carries in one hour if each step is used as designed. It is the number of steps that pass per minute, times 60, times the persons per step. For a step width of 40 in, the value is about 1.5 persons per step, and for 32 in it is 1. The result is the maximum, and it is never reached in practice.

What is the utilization factor?

The utilization factor is the part of the theoretical capacity that is really used, because the passengers do not fill every step. It is lower when the passengers carry luggage, when they hesitate at the entry or when the crowd is not regular. A value of 0.75 to 0.85 is common for the peak flow in a busy station or in a shopping center, and the practical capacity is the product of the two.

How is the number of escalators found?

The peak demand of the passengers, in persons per hour, is divided by the practical capacity of one escalator, and the result is rounded up to the next whole number. In many buildings, one more escalator is provided as a reserve, or the stairs are kept next to it, so that the flow can continue during the maintenance or a breakdown of one unit.

What are the limits of the calculator?

The calculator uses the geometry of the steps and a fixed utilization factor. It does not take into account the queue at the entry, the effect of the width of the landing, the stopping of the escalators in an emergency, the flow in both directions, the direction of the flow that changes with the time of the day or the capacity of the exit at the top and at the bottom. The design must follow the standard and the manufacturer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.