Form tie spacing and capacity calculator for concrete wall forms

Enter the concrete pressure, the safe working load of the tie, the spacing and the size of the wall to get the load on a tie, the ratio, the largest spacing and the number of ties.

Updated on
Your inputs
psf

Value out of range

lb

Value out of range

in

Value out of range

in

Value out of range

ft

Value out of range

ft

Value out of range

Results

Ratio of the load to the safe working load

0.80

The ties can carry the pressure
Load on one tie
2,400 lb
Largest square spacing
26.8 in
Number of ties
105

The form tie spacing and capacity calculator gives the load on one tie, the ratio to the safe working load, the largest square spacing and the number of ties of a concrete wall form, from the lateral pressure of the concrete, the capacity of the ties and the size of the wall.

How the calculation works

  • Enter the lateral pressure of the concrete and the safe working load of the ties.
  • Enter the horizontal and vertical spacing of the ties.
  • Enter the length and the height of the wall to get the load on a tie, the ratio, the largest spacing and the number of ties.

Example

The concrete presses on the forms with 600 psf. A tie at 24 in by 24 in carries 600 × 24 × 24 / 144 = 2,400 lb, a ratio of 0.80 of a 3,000 lb tie. The largest square spacing is √(3,000 / 600) × 12 = 26.8 in. A wall of 42 ft by 10 ft needs 420 / 4 = 105 ties.

Why it matters

The calculator helps formwork carpenters, site engineers, estimators and students to check the spacing of the ties, to count them for an order, and to see how the pressure of the concrete and the strength of the tie decide the grid.

Good to know

Space the ties closer at the bottom of the wall, where the pressure is the highest, and put an extra tie near the corners and the openings. Use ties that are rated for the pressure, with the right cones and washers. Control the rate of the pour, and do not use a bigger spacing than the plan of the formwork supplier. Check the ties and the cones for damage before each use, and replace any tie that is bent or rusted.

The formwork lateral pressure calculator gives the pressure of the concrete, the concrete formwork calculator estimates the forms, the concrete vibrator spacing calculator plans the vibration and the slab shoring spacing calculator sizes the shores of a slab.

Frequently asked questions

What does a form tie do?

A form tie is a steel rod or a snap tie that goes through a concrete wall and holds the two faces of the forms together against the lateral pressure of the fresh concrete. The tie is cut or broken off at the surface after the stripping. Without the ties, the forms would burst open, and the wall would be out of the shape.

How is the load on a tie found?

The load on a tie is the lateral pressure of the concrete times the tributary area of the tie, that is the horizontal spacing times the vertical spacing. The pressure is not the same over the height, and it is the highest near the bottom, so the ties are spaced closer at the bottom. The load must be under the safe working load of the tie, which includes the safety factor given by the manufacturer.

How is the pressure found?

The lateral pressure depends on the rate of the pour, the temperature, the slump, the unit weight, the use of retarders and the height of the placing. The formwork lateral pressure calculator gives it with the equations of the ACI 347. The pressure at the bottom of the form is limited by the full liquid head, that is the unit weight times the height.

What are the limits of the calculator?

The calculator uses the same pressure for all the ties. It does not check the strength of the walers, of the studs and of the sheathing, the end ties, the bending of the plywood, the tie hardware and the cones, or the extra pressure of the vibration and of the impact. The form must be designed for the maximum pressure at each level.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.