The galvanized coating calculator gives the zinc mass per area, the total zinc on a surface of steel, the zinc left after 25 years and the time to first maintenance of a hot-dip galvanized coating, from its thickness, the corrosion environment and the surface of the steel.
How the calculation works
- Enter the thickness of the zinc coating in mils.
- Choose the environment, which sets the corrosion rate of the zinc.
- Enter the surface of the steel to get the coating mass, the zinc on the surface, the zinc left after 25 years and the time to first maintenance.
Example
A hot-dip galvanized coating of 3.9 mils is 3.9 × 25.4 = 99.1 µm thick. Its mass is 99.1 × 7.14 = 707 g/m², that is 2.32 oz/ft². For 5,000 ft² of steel, the zinc weighs 724 lb. In a suburban environment at 1.5 µm/year, 61.6 µm are left after 25 years, and the first maintenance comes after 99.1 × 0.8 / 1.5 = 52.8 years.
Why it matters
The calculator helps engineers, architects, fabricators, galvanizers and owners to compare the life of a galvanized steel in different environments, to estimate the zinc used on a structure, and to plan the maintenance of a bridge, a fence, a tower or a guardrail.
Good to know
Use the coating thickness measured on the real parts and not only the minimum of the standard. Choose a thicker coating or a duplex system with paint for the marine and industrial environments. Avoid the contact of the zinc with copper and with wet concrete that is not cured, and inspect the coating every few years, because a local repair with zinc-rich paint is easy while the damage is small.
Related tools
The corrosion rate calculator converts a mass loss into a rate, the thermal expansion calculator gives the change of length of a steel member, the spray applied fireproofing thickness calculator gives the fireproofing of steel and the steel column capacity calculator checks a steel column.