The buckling strength of a steel column falls as it gets more slender. The steel column capacity calculator applies the AISC 360 equations to give the slenderness, the elastic buckling stress, the critical stress, the nominal strength and the LRFD and ASD design strengths of the column.
How the calculation works
- Enter the effective length factor K (1.0 for a pinned column, 0.65 for fixed ends, 2.0 for a cantilever) and the unbraced length of the column.
- Enter the radius of gyration r about the weak axis and the gross area A of the section, from the steel tables (for example 2.02 in and 9.13 in² for a W8×31).
- Enter the yield stress Fy (50 ksi for A992 steel). The modulus is E = 29,000 ksi.
- The calculator applies the flexural buckling equations of AISC 360 chapter E: Fe = π²E / (KL/r)², then Fcr = 0.658^(Fy/Fe) Fy for the inelastic range or 0.877 Fe for the elastic range.
Example
A W8×31 column (A = 9.13 in², r = 2.02 in about the weak axis) is 12 ft long, pinned, with K = 1.0 and Fy = 50 ksi. The slenderness is KL/r = 144 / 2.02 = 71.3. The Euler stress is Fe = π² × 29,000 / 71.3² = 56.3 ksi. Since Fy / Fe = 0.888 is below 2.25, Fcr = 0.658^0.888 × 50 = 34.5 ksi. The nominal strength is Pn = 34.5 × 9.13 = 314.8 kips. The design strength is φPn = 0.9 × 314.8 = 283.3 kips, and the allowable strength is 188.5 kips.
Why it matters
The calculator helps structural engineering students, designers and steel detailers to check the capacity of a column, to compare sections and lengths, and to see how the bracing changes the strength. It gives the hand calculation of the code in seconds.
Good to know
Use the weak axis radius of gyration unless the column is braced about it. Check the slenderness: above 200, the code recommends a different member. Remember that the strength falls fast when K or the length increases, since the stress goes with the inverse of the square of the slenderness. Add the bracing points to reduce the unbraced length.
Related tools
The Euler buckling calculator gives the elastic critical load, the beam deflection calculator checks serviceability, the bolt shear capacity calculator sizes the connections and the rebar development length calculator covers reinforced concrete.