Skip to content
Omnikalc

Ground anchor bond length calculator: size a prestressed tieback for a wall or slope

Enter the design load, the hole diameter, the bond stress, the factor of safety, the strand strength and the free length to get the bond length, the number of strands, the total length and the strand utilization.

Updated on
Your inputs
kips

Value out of range

in

Value out of range

Value out of range

ksi

Value out of range

ft

Value out of range

Results

Required bond length

33.2 ft

A practical bond length
Number of 0.6 in strands
5
Total anchor length (free plus bond)
73.2 ft
Strand stress as a share of the allowable 0.6 fpu
85.3 %

The ground anchor bond length calculator gives the bond length, the number of strands and the total length of a prestressed tieback from its design load, the hole diameter, the grout-to-ground bond stress and the factor of safety.

How the calculation works

  • Enter the design load of the anchor and the diameter of the drilled bond zone.
  • Choose the ultimate grout-to-ground bond stress for the soil or rock of the bond zone, and the factor of safety on it.
  • Enter the strand strength and the free length between the wall and the bond zone.
  • The calculator finds the bond length L = FS × P / (π d τ), the number of 0.6 in strands at 0.6 fpu and the total length of the anchor.

Example

A tieback has a design load of 150 kips in medium dense sand (40 psi), in a 6 in hole, with a factor of safety of 2. The bond length is 2 × 150,000 / (π × 6 × 40) = 398 in, or 33.2 ft. A 0.6 in strand has an area of 0.217 in² and an allowable load of 0.6 × 270 × 0.217 = 35.2 kips, so 5 strands are needed (150 / 35.2 = 4.27), loaded at 85.3% of the allowable. With a free length of 40 ft, the total length is 73.2 ft.

Why it matters

The calculator helps geotechnical engineers, contractors and students to make a preliminary design of tiebacks for shoring walls, retaining walls and slopes, to see the effect of the ground bond and of the hole diameter on the length and to size the tendon. It supports a first estimate before the test anchors and the final design.

Good to know

Take the bond stress from the geotechnical report or from local anchor tests, and make verification tests on the first anchors. Take the free length from the failure wedge with an extra 5 to 10 ft (1.5 to 3 m). Protect permanent anchors against corrosion, and check the capacity of the wall and of the waler at the head. The final design must be done and approved by a qualified engineer.

The micropile capacity calculator uses the same grout bond, the pile capacity calculator covers driven piles, the Rankine earth pressure calculator gives the wall load and the retaining wall calculator covers walls.

Frequently asked questions

What is a ground anchor?

A ground anchor, or tieback, is a prestressed tendon of steel strands or bars that is drilled into the ground behind a wall or a slope and grouted at its end, the bond zone. The free length is not bonded to the grout, so it can be stressed, and the load passes to the ground by the bond zone. Anchors hold excavation walls, retaining walls and dam walls, and resist uplift.

How is the bond length found?

The ultimate capacity of the anchor is the surface of the bond zone times the ultimate bond stress between the grout and the ground: Tu = π d L τ. The design load is that capacity divided by a factor of safety of 2 or more for permanent anchors in the FHWA and the PTI recommendations. The bond stresses depend on the soil, the drilling and the grouting method, and an acceptance test with load is always required.

How many strands are needed?

The design load is limited to 60% of the guaranteed ultimate strength of the tendon, and the lock-off load is limited to 70%. Each 0.6 in strand has an area of 0.217 in² (140 mm²) and a strength of 270 ksi (1,860 MPa), which gives an allowable load of about 35 kips (156 kN). The number is rounded up to a whole number, and the strand utilization shows the margin.

What are the limits of the calculation?

The bond stress is the key uncertainty and can vary by a factor of 2 for the same soil with a different grouting. The bond length should be between 10 and 40 ft (3 to 12 m) in practice, because a longer length does not increase the capacity in proportion, as the stress is not uniform. The free length must reach beyond the failure wedge behind the wall, and the anchors need a corrosion protection for permanent use.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.