Enter the hole diameter, the bond length, the bond stress, the steel and grout properties to get the geotechnical capacity from the grout-to-ground bond, the structural capacity and the governing allowable load of a micropile.

Updated on
Your inputs
in

Value out of range

ft

Value out of range

Value out of range

in²

Value out of range

ksi

Value out of range

ksi

Value out of range

Results

Governing allowable capacity

75.4 kips

Ultimate geotechnical capacity (grout-to-ground bond)
150.8 kips
Allowable geotechnical capacity
75.4 kips
Allowable structural capacity
207.3 kips
Geotechnical over structural capacity
0.36
Ground bond governs: lengthen the bond zone to use more of the steel

The micropile capacity calculator gives the geotechnical capacity of a micropile from the grout-to-ground bond, the structural capacity from the steel and the grout, and the governing allowable load, for a given hole diameter and bond length.

How the calculation works

  • Enter the drill hole diameter, the bond length in the bearing soil or rock, and select the ultimate grout-to-ground bond stress for the ground type.
  • Enter the factor of safety on the bond (2 or more for a pressure-grouted micropile).
  • Enter the steel area, the steel yield strength and the grout strength to get the structural capacity from the FHWA formula 0.40 f′c Agrout + 0.47 fy Asteel.
  • The calculator gives the geotechnical capacity π d L α, the structural capacity and the governing allowable load.

Example

A micropile has an 8 in hole with a 25 ft bond length in dense silt and fine sand (20 psi). The ultimate geotechnical capacity is π × 8 × 300 × 20 = 150.8 kips, or 75.4 kips allowable at a factor of safety of 2. The steel is 3 in² at 80 ksi and the grout 5 ksi, so the grout area is 47.27 in² and the structural capacity is 0.4 × 5 × 47.27 + 0.47 × 80 × 3 = 207.3 kips. The ground bond governs with 75.4 kips.

Why it matters

The calculator helps foundation engineers, underpinning contractors, structural engineers and students to make a preliminary design of micropiles, to estimate the bond length for a required load and to see which part of the pile governs. It supports a first sizing before a test pile and a detailed design.

Good to know

Choose the bond stress from the geotechnical report and the grouting method of your contractor. Confirm the design with a verification load test. Reduce the steel area for corrosion in aggressive soils. Check the settlement and the group effect, and have the final design done by a qualified engineer.

The pile capacity calculator covers driven piles in clay, the pile group efficiency calculator covers groups, the bolt shear capacity calculator covers steel connections and the soil unit weight calculator converts soil weights.

Frequently asked questions

What is a micropile?

A micropile is a small-diameter drilled and grouted pile, usually 4 to 12 inches (100 to 300 mm) in diameter, reinforced with a steel casing, a bar or both. It is installed with small drilling rigs in places where access or headroom is limited, such as inside buildings, and in difficult ground. Micropiles carry the load mainly through the bond between the grout and the ground along the bond zone.

How is the geotechnical capacity found?

The ultimate capacity is the surface of the bond zone times the ultimate grout-to-ground bond stress: Pu = π d L α. The bond stress depends on the soil or rock, on the grouting method and on the pressure used. The values here are typical order-of-magnitude values from FHWA guidance for pressure-grouted micropiles, and a load test is used to confirm the design in a real project.

How is the structural capacity found?

The allowable compressive structural capacity is the sum of the contribution of the grout, 0.40 f′c times its area, and of the steel, 0.47 fy times its area, according to the FHWA micropile manual. The casing area can be reduced for corrosion over the life of the pile. A tension capacity depends on the steel only, and the buckling in very soft soils has to be checked separately.

Which capacity governs?

In most soils, the bond with the ground is smaller than the structural capacity, so the length of the bond zone is the design variable that sets the load. The calculator shows the ratio of the two. If the ratio is above one, more bond length does not help, and the steel or the grout must be increased. The overall pile system is also checked for settlement and for group effects.