The mass concrete temperature calculator gives the adiabatic temperature rise, the rise of the section, the peak temperature at the core and the differential between the core and the surface of a thick concrete element, from the cement content, the heat of hydration and the placing temperature.
How the calculation works
- Enter the cementitious content, the heat of hydration of the cement and the unit weight of the concrete.
- Choose the size of the section, which sets the share of the adiabatic rise that is reached, and enter the placing and ambient temperatures.
- The calculator finds the adiabatic temperature rise, the rise of the section, the peak temperature at the core and the differential between the core and the surface.
Example
A concrete with 350 lb/yd³ of cementitious material and a heat of hydration of 80 cal/g (144 BTU/lb) weighs 150 pcf. The adiabatic rise is 350 × 144 / (150 × 27 × 0.22) = 56.6 °F. For a section of about 5 ft (factor 0.6), the rise is 33.9 °F. With a placing temperature of 65 °F, the peak at the core is 98.9 °F, and with an ambient temperature of 70 °F the differential is 28.9 °F, below the 35 °F limit.
Why it matters
The calculator helps concrete engineers, contractors, quality managers and students to estimate the heat of a large pour such as a footing, a mat or a dam, to see the effect of the cement content and of the placing temperature and to decide if a thermal control plan is needed.
Good to know
Reduce the cement content with fly ash or slag, cool the aggregates and the mixing water, place the concrete at a low temperature and use insulation to keep the surface warm. Install temperature sensors in the core and near the surface, and keep a record until the differential falls.
Related tools
The concrete curing calculator helps to plan the curing, the concrete volume calculator gives the volume of the pour, the concrete crack width calculator checks the cracks and the bridge expansion joint movement calculator shows the thermal movements.