Skip to content
Omnikalc

Prestressing strand transfer and development length calculator

Enter the strand diameter, the effective stress, the stress at nominal strength and the distance to the critical section to get the transfer length, the development length and the ratio.

Updated on
Your inputs
in

Value out of range

ksi

Value out of range

ksi

Value out of range

in

Value out of range

Results

Development length

68.3 in

Transfer length
28.3 in
Flexural bond length
40.0 in
Distance available to development length
1.17
The strand is fully developed at the critical section
Rule of thumb of 50 diameters
25.0 in

The prestressing strand transfer and development length calculator gives the transfer length, the flexural bond length and the development length of a strand in a pretensioned member with the ACI 318 formula.

How the calculation works

  • Enter the diameter of the strand, the effective stress after losses and the stress at nominal strength.
  • Enter the distance from the end of the member to the critical section.
  • The calculator gives the transfer length, the flexural bond length, the development length and the ratio of the distance available to the development length.

Example

A pretensioned strand of 1/2 in has an effective stress of 170 ksi and a stress of 250 ksi at nominal strength. The transfer length is (170 / 3) × 0.5 = 28.3 in. The flexural bond length is (250 − 170) × 0.5 = 40.0 in, so the development length is 68.3 in. A critical section 80 in from the end is 1.17 times that length. The rule of thumb of 50 diameters gives 25 in for the transfer length.

Why it matters

The calculator helps precast designers, structural engineers, inspectors and students to check how close to the end of a pretensioned beam or slab the strands are fully effective, and to see how the stresses and the strand size change the lengths.

Good to know

Use the effective stress after all the losses for fse, and the stress at nominal strength fps from the strain compatibility analysis or the code equation. Check the sections near the end of the member against the available distance, and look at the shear and the bending capacity in the transfer zone. If the development length is more than the available length, use strands of a smaller diameter, a higher concrete strength, an extra bonded reinforcement or an anchorage. For debonded strands, increase the development length by the factor required by the code, which is two for flexural bond in many codes.

The tendon friction loss calculator gives the losses of a post-tensioned tendon, the anchorage zone calculator gives the bursting force at an anchor, the rebar development length calculator gives the anchorage of bars and the shear friction calculator checks a crack interface.

Frequently asked questions

What is the transfer length?

In a pretensioned member, the strands are tensioned between abutments and the concrete is cast around them. When the strands are cut, the prestress is transferred to the concrete by bond over a length at the end of the member, the transfer length, where the stress in the strand rises from zero to the effective stress.

What is the development length?

The development length is the length from the end of the member that the strand needs to reach its stress at nominal strength fps, and so to resist the bending moment at a section. It is the transfer length plus the flexural bond length, and ACI 318 writes it as ld = (fse / 3000) db + ((fps − fse) / 1000) db, in inches with the stresses in psi.

Why is it important?

Close to the end of a member, the strands cannot yet develop their full strength, and the moment and shear capacity of the sections in this zone are reduced. Short beams, deep members, members with large loads near the ends and members with debonded strands need the check of the development length. It also affects the cracking and the anchorage of the end zone.

What does the calculator leave out?

The calculator leaves out the effect of debonded strands, which need a longer length, the type of the strand surface, the release of the strands by flame cutting, the confinement by stirrups and the concrete strength at release. Use the code provisions for the section and the project, since the codes differ in the details.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.