Tendon friction loss calculator: force along a post-tensioned tendon

Enter the jacking force, the friction and wobble coefficients, the angular change and the length of a post-tensioned tendon, with the anchor set, to get the force at the far end, the friction loss and the effect of the anchor seating.

Updated on
Your inputs
kips

Value out of range

Value out of range

rad

Value out of range

Value out of range

ft

Value out of range

in

Value out of range

ksi

Value out of range

in²

Value out of range

Results

Force at the far end

173.2 kips

Friction exponent μα + Kx
0.1440
Friction loss along the tendon
13.4 %
Length affected by the anchor set
28.5 ft
Force at the live end after seating
174.5 kips
Seating length as a fraction of the tendon length
0.48
The anchor set is absorbed within the tendon length

In a post-tensioned member, the force in a tendon is lower away from the jack because of the friction with the duct and the anchor set. The tendon friction loss calculator applies the ACI 318 friction equation to find the force at the far end, the loss and the length affected by the seating of the anchor.

How the calculation works

  • Enter the jacking force applied at the live end of the post-tensioned tendon and the length of the tendon.
  • Enter the curvature friction coefficient μ (about 0.15 to 0.25 for strands in a plastic or metal duct), the total angular change α of the tendon profile in radians, and the wobble coefficient K per foot (0.0010 to 0.0020).
  • The calculator applies the friction equation of ACI 318: Pe = Pj × e^−(μα + Kx), which gives the force at the far end and the loss along the tendon.
  • Enter the anchor set, the modulus and the area of the steel to find the length of the tendon that loses force when the wedges seat, and the force at the live end after seating.

Example

A tendon of 60 ft is jacked to 200 kips, with μ = 0.20, a total angular change of 0.30 rad and K = 0.0014 per ft. The exponent is 0.20 × 0.30 + 0.0014 × 60 = 0.1440. The force at the far end is 200 × e^−0.1440 = 173.2 kips, a friction loss of 13.4%. With an anchor set of 0.25 in, E = 28,500 ksi and A = 0.612 in² (4 strands), the seating affects 28.5 ft of the tendon (0.48 of its length), and the force at the live end after seating is 174.5 kips.

Why it matters

The calculator helps prestressed concrete designers, post-tensioning contractors and students to estimate the effective force along a slab or a beam tendon, to check the jacking force and the elongation, and to see how much a longer tendon, a sharper profile or a larger anchor set costs in force. It is the first of the prestress losses.

Good to know

Use the friction coefficients of the post-tensioning system that is installed, not only the default values. Stress long tendons from both ends. Check the measured elongation against the calculated one, and investigate a difference of more than 7%. Remember to add the other losses, the long-term ones, to get the effective prestress.

The cracking moment calculator uses the effective prestress, the rebar development length calculator covers the mild steel, the beam deflection calculator checks the camber and the deflection, and the punching shear calculator covers flat slabs with unbonded tendons.

Frequently asked questions

Why does the force drop along a post-tensioned tendon?

A tendon in a duct rubs on the duct when it is jacked. The friction has two parts: the curvature friction, because the tendon presses on the duct where it changes direction, and the wobble friction, from the small unplanned deviations of the duct along its length. The force is highest at the live end, where the jack is, and lowest at the far end. A tendon stressed from both ends reduces the loss.

What is the friction equation?

ACI 318 gives the force at a distance x from the jack as Pe = Pj × e^−(μα + Kx), where μ is the curvature friction coefficient, α the sum of the angular changes of the tendon in radians, and K the wobble coefficient per unit length. Typical values for strands in a galvanized metal duct are μ = 0.15 to 0.25 and K = 0.0010 to 0.0020 per foot (0.0033 to 0.0066 per meter). The supplier of the system gives the values for the duct.

What is the anchor set loss?

When the jack is released, the wedges slip a few millimeters into the anchor before they grip the strands, which relaxes the tendon near the live end. The length affected is found by balancing the shortening with the friction profile: the seating length satisfies Δ Eps Aps = p Lset², where p is the loss of force per unit length. Beyond that length, the force is not changed. The loss is largest at the anchor.

What are the limits of this calculator?

It assumes a constant slope of the force along the tendon, an anchor set that does not reach the far end, and a single jack. It does not include the elastic shortening of the concrete, the creep, the shrinkage and the relaxation of the steel, which are the other losses of a prestressed member. Use it to check the jacking forces of a slab or a beam, and to compare the elongation of the tendon in the field.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.