Rapid sand filter sizing calculator: how big must the filters of a water plant be?

Enter the plant flow, the filtration rate, the number of filters, the backwash rate and duration and the filter run to get the area of a filter, the rate with all in service, the backwash flow and volume and the share of backwash water.

Updated on
Your inputs
MGD

Value out of range

gpm/ft²

Value out of range

gpm/ft²

Value out of range

min

Value out of range

Value out of range

h

Value out of range

Results

Area of each filter (one filter out of service)

115.7 ft²

Filtration rate with all the filters in service
3.00 gpm/ft²
Backwash flow of one filter
1,736 gpm
Volume of one backwash
17,361 gal
Backwash water as a share of production
1.74 %

The rapid sand filter sizing calculator gives the area of each filter of a water treatment plant for a design flow and filtration rate, with one filter out of service, the rate with all in service, and the backwash flow, volume and share of the production.

How the calculation works

  • Enter the plant flow in MGD, the design filtration rate and the number of filters.
  • Enter the backwash rate, its duration and the length of the filter run between two backwashes.
  • The calculator sizes the area of each filter so that the plant can treat the design flow with one filter out of service, and gives the filtration rate with all the filters in service, the backwash flow and volume, and the backwash water as a share of the production.

Example

A plant of 2 MGD (1,389 gpm) is designed at 4 gpm/ft² with 4 filters. The total area is 1,389 / 4 = 347 ft², and with one filter out of service each of the 3 others has 115.7 ft². With all 4 in service the rate is 3.00 gpm/ft². A backwash at 15 gpm/ft² needs 1,736 gpm for 10 min, which is 17,361 gal. With a run of 48 h, the backwash water is 1.74% of the production.

Why it matters

The calculator helps water treatment engineers, plant operators, municipal planners and students to size the filters of a plant in a first design, to see the effect of the number of filters and of the backwash rate, and to estimate the backwash water to be treated. It reproduces the typical hand calculation of a design.

Good to know

Use the filtration rate allowed by the authority for the type of filter, and a number of filters that gives a good redundancy. Design the backwash for the cold water, which is more viscous, and provide a storage tank for the backwash water. Add the area for the future expansion, and design the filters with a margin on the loading rate.

The chemical feed rate calculator sizes the chemical dosing, the detention time calculator gives the retention time of the tanks, the Stokes law calculator gives the settling velocity of the particles and the pump power calculator sizes the backwash pumps.

Frequently asked questions

What is a rapid sand filter?

A rapid sand filter is a granular filter used in water treatment after the coagulation and the sedimentation, in which the water flows down through a bed of sand or sand and anthracite, at 2 to 8 gpm/ft², and the particles are retained in the bed. When the filter loses its capacity, because of the head loss or the turbidity of the effluent, it is cleaned by a backwash, with a reverse flow that expands the bed and washes the particles.

Why is one filter out of service?

A plant must be able to produce its design flow when a filter is being backwashed or repaired. The area of each filter is therefore computed so that the other filters, with one out of service, carry the design rate. With all the filters in service the actual rate is lower. The more filters there are, the smaller the area that has to be added for this redundancy, which is why plants have at least four filters.

How is the backwash water computed?

The backwash flow is the backwash rate multiplied by the area of the filter, the rate being high enough to expand the bed by 20 to 50%, usually 15 to 20 gpm/ft². The volume of a backwash is this flow multiplied by the duration, often 5 to 15 minutes, and the share of the production is the volume used in the filter run divided by the water produced, which is generally 2 to 5%. The backwash water is often treated and recycled.

What are the limits of the calculator?

The calculator sizes the areas and the volumes. It does not design the media depth and the grain size, the underdrain, the air scour, the wash troughs, the head loss, the filter-to-waste or the piping. The rates allowed are fixed by the regulations of the region, and depend on the type of filter and the pretreatment. A qualified engineer must design the filters, with the approval of the authority.