Relief valve gas sizing calculator: required orifice area for gas or vapor

Enter the relieving flow, the set pressure, the temperature and the gas properties to get the API 520 required orifice area of a safety relief valve for gas, and the next standard orifice size.

Updated on
Your inputs
lb/h

Value out of range

psig

Value out of range

°F

Value out of range

Value out of range

Value out of range

Value out of range

Value out of range

Results

Required orifice area

1.015 in²

Next standard API orifice area
1.287 in²
API orifice J (1.287 in²)
Relieving pressure (absolute)
124.7 psia
Gas coefficient C
356.1
Share of the standard orifice used
78.9 %
The selected orifice covers the required area

The relief valve gas sizing calculator applies the API 520 formula for critical flow to give the required orifice area of a pressure relief valve for gas or vapor, together with the next standard orifice (letters D to T) and the relieving pressure.

How the calculation works

  • Enter the required relieving flow of gas, the set pressure of the valve and the overpressure that is allowed (10% for a single valve, 21% for fire).
  • Enter the relieving temperature, the molecular weight, the ratio of specific heats k and the compressibility factor Z of the gas, and the discharge coefficient Kd (0.975 for most valves).
  • The calculator applies the API 520 critical flow formula A = W / (C Kd P1 Kb Kc) × √(T Z / M) with C = 520 √[k (2 / (k + 1))^((k + 1) / (k − 1))].
  • It gives the required orifice area, the next standard API orifice (D to T) and how much of it is used.

Example

A vessel must relieve 10,000 lb/h of air (M = 28.97, k = 1.4) at 100 °F from a valve set at 100 psig with 10% overpressure. The relieving pressure is 100 × 1.1 + 14.7 = 124.7 psia and C = 356.1. The required area is 10,000 / (356.1 × 0.975 × 124.7) × √(559.67 / 28.97) = 1.015 in². The next standard size is the J orifice (1.287 in²), which is used at 78.9%.

Why it matters

The calculator helps process safety engineers, plant designers, inspectors and students to make a quick check of the size of a safety valve, to compare scenarios and to see how overpressure, temperature and gas properties change the area. It is a first estimate before the manufacturer’s sizing and the formal relief study.

Good to know

Use the worst case relieving flow and the gas properties at the relieving conditions. Check the inlet loss, which must stay under 3% of the set pressure, and the back pressure. Confirm the certified capacity of the chosen valve. Have the final sizing done by a qualified engineer, as an under-sized valve is a serious safety risk.

The pressure tank calculator covers the vessel, the ideal gas calculator gives the gas density and volume, the orifice flow calculator covers other flow cases and the pump power calculator sizes the machines that feed the vessel.

Frequently asked questions

What is the API 520 gas sizing formula?

For gas or vapor in critical (choked) flow, API 520 gives the area A = W / (C Kd P1 Kb Kc) × √(T Z / M), where W is the mass flow, P1 the absolute relieving pressure, T the absolute temperature, Z the compressibility factor and M the molecular weight. C depends only on the ratio of specific heats k. Kd is the discharge coefficient, Kb the back-pressure factor and Kc the factor for a rupture disk below the valve.

What is the relieving pressure?

It is the pressure at the valve inlet when it is relieving at full flow, which is the set pressure plus the allowed overpressure plus the atmospheric pressure. The code allows 10% overpressure for a single valve, 16% for multiple valves and 21% for a fire case. A higher overpressure gives a higher relieving pressure and a smaller orifice, but the vessel must be designed for the maximum accumulated pressure.

What are the API orifice letters?

API 526 standardizes the orifice areas of flanged safety valves from D (0.110 in²) to T (26.0 in²). The calculator gives the smallest standard orifice that is larger than the required area. The actual area of the valve is often a little different from the nominal one, and the manufacturer’s certified capacity must be used for the final selection.

When is the formula not valid?

The formula is for critical flow, when the back pressure is below about 55% of the relieving pressure. Above that, the flow is subcritical and the equation changes. It also does not cover liquids, steam (which has its own formula), two-phase flow or pilot-operated valves with a large inlet loss. The calculation does not replace the sizing by a competent engineer who also checks the inlet and outlet piping.