Skip to content
Omnikalc

Shear flow and fastener spacing calculator for a built-up beam

Enter the dimensions of a built-up T-section, the shear force and the capacity of a fastener to get the neutral axis, the moment of inertia, the shear flow and the maximum spacing of the nails, screws or bolts.

Updated on
Your inputs
in

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

lb

Value out of range

lb

Value out of range

Value out of range

Results

Maximum fastener spacing

2.11 in

Neutral axis (from the top)
3.76 in
Moment of inertia I
277.1 in⁴
First moment Q of the flange
32.77 in³
Shear flow q = V Q / I
94.6 lb/in

When a beam is built from several parts, the fasteners must carry the shear flow between them. The shear flow and fastener spacing calculator finds the neutral axis, the moment of inertia, the first moment, the shear flow and the maximum spacing of nails, screws or bolts in a built-up T-section.

How the calculation works

  • Enter the flange width and thickness and the web thickness and height of the built-up T-section, for example two boards of lumber nailed together.
  • Enter the shear force V in the section and the shear capacity of one fastener (a nail, a screw or a bolt).
  • Enter the number of rows of fasteners that connect the flange to the web.
  • The calculator finds the neutral axis, the moment of inertia I and the first moment Q of the flange, then the shear flow q = V Q / I and the maximum spacing s = n P / q.

Example

A T-beam is built from a flange of 7.25 in × 1.5 in and a web of 1.5 in × 9.25 in, with V = 800 lb. Fasteners of 100 lb each are placed in 2 rows. The areas are 10.875 and 13.875 in², and the neutral axis is 3.763 in below the top. The moment of inertia is 277.1 in⁴ and the first moment of the flange is Q = 10.875 × 3.013 = 32.77 in³. The shear flow is q = 800 × 32.77 / 277.1 = 94.6 lb/in. The maximum spacing is s = 2 × 100 / 94.6 = 2.11 in.

Why it matters

The calculator helps structural engineering students, carpenters and designers to size the connection of built-up beams, such as nailed or screwed wood members, and to see how the shear force and the fastener capacity change the spacing. It saves a long calculation of centroids and moments of inertia.

Good to know

Use a spacing smaller than the maximum, and make it smaller near the supports where the shear is high. Use the lowest design capacity of the fastener, including the edge distance and the penetration. Consider the slip of the connection for deflection, and check the bending and the shear of the parts themselves.

The moment of inertia calculator gives the section stiffness, the wood beam span calculator sizes lumber beams, the beam deflection calculator checks serviceability and the bolt shear capacity calculator gives the strength of a bolted connection.

Frequently asked questions

What is the shear flow?

The shear flow q is the horizontal shear force per unit length that acts between the parts of a built-up beam when it bends. It is given by q = V Q / I, where V is the shear force in the section, Q is the first moment about the neutral axis of the area that is connected, and I is the moment of inertia of the whole section. The fasteners or the welds must carry this force along the beam.

How is the fastener spacing found?

Each fastener resists a force P in shear. If there are n fasteners at each location, they resist n × P over the spacing s. Setting n P / s equal to q gives the maximum spacing s = n P / q. Use a smaller spacing in practice, in whole numbers of inches or millimeters, and increase the number of fasteners where the shear force is larger, near the supports.

What is Q for a T-section?

To connect the flange to the web, Q is the first moment of the flange area about the neutral axis of the whole section: the area of the flange multiplied by the distance from its centroid to the neutral axis. This is the part of the section that would slip over the web if there were no fasteners. For other cuts, such as a point in the web, the area above the cut is used.

What are the limits of this calculator?

It assumes a full composite action, which means that the fasteners are rigid enough that the two parts do not slip. Nailed or screwed wood beams have a slip that reduces the real stiffness, and mechanically connected beams need an effective stiffness factor. It also assumes elastic behavior, a uniform fastener capacity and a constant shear force over the spacing.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.