Shear wall calculator: check a wood shear wall segment and find the hold-down tension

Enter the lateral load, the wall height and length, the allowable unit shear and the dead load to get the unit shear demand, the aspect ratio, the demand over capacity and the hold-down tension.

Updated on
Your inputs
lb

Value out of range

ft

Value out of range

ft

Value out of range

plf

Value out of range

plf

Value out of range

Results

Demand over capacity

0.89

The wall can carry the load
Unit shear demand
250 plf
Aspect ratio (height over length)
1.00
Aspect ratio of 2:1 or less: full capacity
Allowable unit shear after the aspect ratio reduction
280 plf
Hold-down tension at each end
1,280 lb

The shear wall calculator checks a wood shear wall segment against a lateral load: the unit shear, the aspect ratio with its reduction, the demand over capacity and the hold-down tension from the overturning moment and the dead load.

How the calculation works

  • Enter the lateral load (wind or seismic, ASD level) on the shear wall segment, the wall height and the length of the segment.
  • Enter the allowable unit shear of the sheathing and nailing schedule from the code table (such as the SDPWS).
  • Enter the dead load on the wall, which resists the overturning together with the hold-downs.
  • The calculator finds the unit shear v = V / L, the aspect ratio and its reduction, the demand over capacity and the hold-down tension.

Example

A shear wall segment 8 ft high and 8 ft long takes a lateral load of 2,000 lb, with sheathing allowing 280 plf and a dead load of 300 plf. The unit shear is 2,000 / 8 = 250 plf. The aspect ratio is 1.0, so there is no reduction, and the demand over capacity is 250 / 280 = 0.89. The overturning moment is 2,000 × 8 = 16,000 lb·ft and the dead load resists 0.6 × 300 × 8 × 4 = 5,760 lb·ft, so the hold-down tension is (16,000 − 5,760) / 8 = 1,280 lb.

Why it matters

The calculator helps builders, engineers, designers and students to do the first check of the bracing of a wood-frame building, to see how long a wall must be for a given nailing and to size the hold-downs. It reproduces the hand calculation behind the shear wall tables of the code.

Good to know

Use the allowable unit shear from the code table for the exact sheathing, the nails and the spacing, and the ASD or LRFD load level consistently. Do not count the wall segments with an aspect ratio above 3.5. Check the wall separately in each direction and at each story, and the load path from the roof to the foundation. A licensed engineer must design the lateral system of a real building.

The wood beam span calculator covers beams, the floor joists calculator covers floors, the load combinations calculator gives the factored loads and the wind load calculator gives the wind pressure.

Frequently asked questions

What is a shear wall?

A shear wall is a wall braced against lateral loads from the wind or earthquakes. In a wood frame it is made of studs sheathed with structural panels such as plywood or OSB nailed at a specified spacing. The wall acts like a deep cantilever beam and carries the horizontal load from the roof and floors down to the foundation. Its capacity depends on the panel, the size and the spacing of the nails and the length of the wall.

How is the unit shear found?

The unit shear is the lateral load divided by the length of the wall, in lb per foot or kN per meter. It is compared with the allowable unit shear of the sheathing and nailing in the code tables, such as the AWC Special Design Provisions for Wind and Seismic (SDPWS), which gives values for each combination of panel, nail and edge spacing. The allowable values are for ASD loads, and the nominal values are higher.

What is the aspect ratio rule?

A tall narrow wall is more flexible, so the codes limit the aspect ratio of the wall height to its length. Up to 2:1 the full capacity applies. Between 2:1 and 3.5:1 the allowable shear is reduced by the factor 2 b / h, and above 3.5:1 the segment cannot be counted as a shear wall. A wall with large openings is made of several segments, each checked separately.

How is the hold-down force found?

The lateral load tries to tip the wall over. The overturning moment is the load times the height, and the dead load on the wall resists it with a lever arm of half the length, with a factor of 0.6 for the ASD combination. The remaining moment divided by the length is the tension that the hold-down at each end must carry to the foundation. The hold-down, the anchor bolts, the sill and the posts need to be checked too.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.