Skip to content
Omnikalc

Sign post wind load and overturning moment calculator

Enter the size of the sign, the height, the wind speed, the coefficients, the allowable stress and the soil pressure to get the wind force, the overturning moment, the post size and the footing depth.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft

Value out of range

mph

Value out of range

Value out of range

Value out of range

Value out of range

ksi

Value out of range

psf

Value out of range

ft

Value out of range

Results

Section modulus required

5.18 in³

Velocity pressure
17.63 psf
Wind force on the sign
863 lb
Overturning moment at the ground
10,355 ft·lb
Embedment depth of the footing
7.1 ft

The sign post wind load calculator gives the velocity pressure, the wind force on the sign, the overturning moment at the ground, the section modulus required for the post and the embedment depth of the footing, from the size of the sign, the wind speed and the soil.

How the calculation works

  • Enter the width and the height of the sign and the height of its centre above the ground.
  • Enter the design wind speed, the exposure, gust and force coefficients, the allowable stress of the post and the soil pressure.
  • Enter the diameter of the footing to get the wind force, the overturning moment, the section modulus and the embedment depth.

Example

A sign of 8 ft by 4 ft has its centre 12 ft above the ground in a wind of 90 mph. The velocity pressure is 0.00256 × 0.85 × 90² = 17.63 psf. The force is 17.63 × 0.85 × 1.8 × 32 = 863 lb, and the moment at the ground is 863 × 12 = 10,355 ft·lb. With an allowable stress of 24 ksi, the post needs a section modulus of 5.18 in³. A footing of 2 ft in a soil of 400 psf needs an embedment of 7.1 ft.

Why it matters

The calculator helps sign contractors, shop owners, landscapers, site managers and students to size the post and the footing of a billboard, a monument sign or a banner, to see how much a larger sign or a higher wind raises the moment, and to check a quote or a drawing quickly.

Good to know

Use the design wind speed of the local code for the risk category and the exposure of the site, and not the speed of a forecast. A sign on the edge of a hill or open ground has a higher exposure coefficient. Check the soil with a probe or a report before the pour, keep the concrete around the post cured for a few days before the sign is hung, and add a safety margin when the soil is soft or wet.

The wind load calculator gives the pressure on a building, the flagpole footing calculator gives the depth and the concrete of a pole, the site hoarding wind load calculator gives the ballast of a fence and the base plate size calculator sizes the plate at the bottom of a steel post.

Frequently asked questions

How is the wind force on a sign found?

The force is the velocity pressure times the gust factor times the force coefficient times the area of the sign. The velocity pressure is 0.00256 times the exposure coefficient times the speed in miles per hour squared. A solid sign on posts has a force coefficient near 1.8 for a wide sign, and less for a sign that is taller than it is wide.

How is the post checked?

The wind force acts at the centre of the sign, so the moment at the ground is the force times the height of the centre. The calculator divides this moment by the allowable stress to get the section modulus that the post needs. Choose a steel pipe or a section with a modulus at least as large, and check the base plate and the connections.

How is the footing depth found?

The calculator uses the non-constrained pole formula of the building codes, where the depth depends on the force, the allowable lateral soil pressure at one third of the depth and the diameter of the footing. A wider footing needs less depth. The result is a first estimate, and the local code and the soil report decide.

What are the limits of the calculator?

The calculator uses a single wind force at the centre of the sign. It does not include the torsion of an eccentric sign, the fatigue, the ice, the seismic load, the dead load, the frost heave or the check of the sign frame. Large signs, signs near a roadway and tall pylons need a sealed design by an engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.