Guardrail post load, base moment and anchor calculator

Enter the rail height, the post spacing, the loads and the post size to get the design load, the moment at the base, the anchor tension and the bending stress of a guardrail post.

Updated on
Your inputs
in

Value out of range

in

Value out of range

plf

Value out of range

lb

Value out of range

in

Value out of range

in

Value out of range

psi

Value out of range

in

Value out of range

Results

Stress to allowable stress

0.73

The post resists the guard load
Design load on the post
200 lb
Moment at the base of the post
8,400 lb-in
Tension in the anchor
2,400 lb
Bending stress in the post
1,176 psi

The guardrail post calculator gives the design load of a post under the 50 plf or 200 lb guard load, the moment at the base, the tension in the anchors and the bending stress of the post.

How the calculation works

  • Enter the height of the top rail, the post spacing, the line load and the minimum concentrated load.
  • Enter the size of the post, its allowable bending stress and the lever arm between the anchors.
  • The calculator gives the design load, the base moment, the anchor tension, the bending stress and the ratio to the allowable stress.

Example

A guard has posts at 48 in with a top rail 42 in high, designed for 50 plf or a concentrated load of 200 lb. The load on a post is the larger of 200 lb and 50 × 48 / 12 = 200 lb, so 200 lb. The moment at the base is 200 × 42 = 8,400 lb-in. With anchors 3.5 in apart the tension is 2,400 lb. A 3.5 × 3.5 in post has a section modulus of 7.146 in³ and a stress of 1,175.5 psi, which is 0.73 of an allowable stress of 1,600 psi.

Why it matters

The calculator helps deck builders, carpenters, fabricators, inspectors and engineers to check a guard post and its anchors, to see how the height and the spacing change the forces, and to choose a post size or a base plate.

Good to know

Measure the height from the walking surface to the top of the rail, and use the load of your code and the type of building, since public buildings have higher loads than houses. Check the post in both directions if the post is not square. The anchor tension is large for a tall post with a short lever arm, so a wider base plate or a deeper embedment helps a lot. Make sure that the wood or concrete that holds the anchors is strong enough, because most guard failures come from the connection to the structure and not from the post itself.

The sign post wind load calculator gives an overturning moment, the stair handrail calculator lays out a handrail, the bolt shear calculator checks the anchors and the base plate calculator sizes the plate under a post.

Frequently asked questions

What load must a guard resist?

In the International Building Code, a guard must resist a load of 50 pounds per foot applied at the top, or a concentrated load of 200 pounds applied at any point in any direction, whichever gives the worse effect. The two do not act together. The load on a post is the line load times the post spacing, but not less than the concentrated load.

How is the post checked?

The load acts at the top of the post and makes a moment at the base equal to the load times the height. The bending stress is the moment divided by the section modulus of the post, which is b d² / 6 for a rectangle. The anchors resist the moment as a couple, so the tension in one anchor is the moment divided by the lever arm.

Which allowable stress should I use?

For a wood post, use the allowable bending stress for the species and grade, with the load duration factor that your code allows for a guard load, which is often 1.33 or 1.6. For steel or aluminum, use the allowable stress of the code that you follow. The calculator takes the value you enter without adjusting it.

What does the calculator leave out?

The calculator leaves out the infill load, the deflection of the top rail, the connection of the rail to the post, the strength of the base material around the anchors and the local rules for a different load. Check the rail, the infill and the supporting structure, and the loads for the type of building.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.