Skip to content
Omnikalc

Steel B1 moment amplification factor calculator

Enter the axial load, the end moments, the section properties and the length of a braced steel column to get Cm, Pe1, the factor B1 and the amplified moment.

Updated on
Your inputs
kips

Value out of range

kip-ft

Value out of range

Value out of range

in²

Value out of range

in⁴

Value out of range

ksi

Value out of range

ft

Value out of range

Value out of range

Results

Amplification factor B1

1.139

A noticeable amplification: check the second-order effects carefully
Coefficient Cm
1.000
Elastic buckling load Pe1
5,330 kips
Stiffness reduction factor τb
0.910
Amplified moment
136.7 kip-ft
Axial load to Pe1
0.122

The steel B1 moment amplification calculator gives Cm, the elastic buckling load Pe1, the stiffness reduction factor, the factor B1 and the amplified moment of a braced steel beam-column.

How the calculation works

  • Enter the required axial load and the larger end moment from the first-order analysis, with the end moment ratio.
  • Enter the area, the moment of inertia, the yield stress, the unbraced length and the design method.
  • The calculator gives the elastic buckling load, the stiffness reduction factor, the amplification factor B1 and the amplified moment.

Example

A column with an area of 20 in², an inertia of 722 in⁴ and a yield stress of 50 ksi is 14 ft long in a braced frame, with an LRFD axial load of 650 kips and a first-order moment of 120 kip-ft in single curvature (M1/M2 = −1). The load is 0.65 of the yield load Py = 1,000 kips, so the stiffness is reduced by τb = 0.91. The buckling load is Pe1 = 5,330 kips, and Cm = 1.00. The amplification factor is B1 = Cm / (1 − Pr / Pe1) = 1.139, so the moment becomes 136.7 kip-ft.

Why it matters

The calculator helps structural engineers and students to see how much the axial load increases the design moment of a braced steel column, to check when the amplification matters and to see the effect of the length, the section and the moment ratio.

Good to know

If B1 is close to 1.0, the second-order effect is small, but you should still include it in the interaction check of the column. If B1 is above 1.5, use a stiffer section, a shorter unbraced length or a second-order analysis. Remember to add the sway amplification B2 to the moments from the lateral loads and to use the factored loads for LRFD and the service loads times 1.6 for ASD.

The steel column capacity calculator gives the axial strength, the Euler buckling calculator gives the elastic buckling load, the steel beam lateral-torsional buckling calculator gives the bending capacity and the seismic story drift calculator gives the stability coefficient of a story.

Frequently asked questions

What is the B1 factor?

B1 is the amplification of the moment of a beam-column that comes from the axial load acting on the bending deflection of the member, the P-δ effect. It is applied to the first-order moment of the members in a braced frame, M r = B1 Mnt, in the amplified first-order method. B1 is at least 1.0, and it grows when the axial load approaches the elastic buckling load of the member.

What is the formula?

B1 = Cm / (1 − α Pr / Pe1) and it is not less than 1. Pe1 = π² EI* / (K1 L)², where EI* = 0.8 τb EI is the reduced stiffness, with τb = 1 if α Pr / Py is at most 0.5 and τb = 4 (α Pr / Py)(1 − α Pr / Py) above it. The coefficient is Cm = 0.6 − 0.4 M1 / M2 for a member with no transverse load, with M1 / M2 negative for single curvature. α is 1.0 for LRFD and 1.6 for ASD.

What does Cm mean?

Cm accounts for the shape of the moment diagram. A column bent in single curvature, with equal end moments, has its maximum moment at mid-height where the deflection is largest, so Cm is 1.0. A column in double curvature has a smaller moment at mid-height, so Cm goes down to 0.2. This calculator is for members without transverse loads between the ends. With a transverse load, Cm is taken as 1.0 or found by analysis.

What are the limits of the calculation?

B1 covers the P-δ effect in a braced frame. The effect of the sway of the frame, the P-Δ effect, is covered by another factor B2 or by a second-order analysis. The calculator also assumes elastic buckling in the plane of the bending, with K1 equal to 1 for a braced frame, and leaves out the buckling out of plane, the lateral-torsional buckling and the capacity checks of the member. It is not a code check.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.