Steel beam lateral-torsional buckling calculator: moment capacity for an unbraced length

Enter the section properties, the yield stress, the unbraced length and the Cb factor to get the limiting lengths Lp and Lr, the plastic moment, the nominal strength Mn and the design strength φMn of a doubly symmetric I-beam.

Updated on
Your inputs
in³

Value out of range

in³

Value out of range

in

Value out of range

in

Value out of range

in⁴

Value out of range

in

Value out of range

ksi

Value out of range

ft

Value out of range

Results

Design flexural strength, φMn (LRFD)

210.5 kip-ft

Limiting length for full plastic moment, Lp
5.55 ft
Limiting length for inelastic buckling, Lr
16.15 ft
Plastic moment, Mp
304.2 kip-ft
Nominal flexural strength, Mn
233.9 kip-ft
Nominal strength as a share of the plastic moment
76.9 %
Inelastic lateral-torsional buckling reduces the strength: add bracing

The steel beam lateral-torsional buckling calculator gives the flexural strength of a doubly symmetric wide-flange beam for a given unbraced length, with the limiting lengths Lp and Lr, the plastic moment and the design strength φMn according to AISC 360.

How the calculation works

  • Enter the section properties from the steel manual: Zx, Sx, ry, rts, J and ho, and the yield stress of the steel.
  • Enter the unbraced length of the compression flange and choose the moment gradient factor Cb.
  • The calculator finds the limiting lengths Lp and Lr and the plastic moment Mp = Fy Zx from AISC 360 chapter F2.
  • It gives the nominal strength Mn for the zone (plastic, inelastic or elastic buckling) and the design strength φMn, with φ = 0.90.

Example

A W16×40 beam has Zx = 73 in³, Sx = 64.7 in³, ry = 1.57 in, rts = 1.89 in, J = 0.794 in⁴, ho = 15.5 in and Fy = 50 ksi, with an unbraced length of 12 ft and Cb = 1.00. Then Lp = 5.55 ft, Lr = 16.15 ft and Mp = 304.2 kip-ft. The length is between Lp and Lr, so Mn = 304.2 − (304.2 − 188.7) × (12 − 5.55) / (16.15 − 5.55) = 233.9 kip-ft, or 76.9% of Mp, and φMn = 0.9 × 233.9 = 210.5 kip-ft.

Why it matters

The calculator helps structural engineers, steel detailers and students to check the moment capacity of a beam between lateral braces, to see how much bracing is needed and to compare different sections. It reproduces the hand calculation of the specification, which is useful for checking the output of structural software.

Good to know

Use the section properties from the steel manual for the exact shape, and a value of Cb of 1.0 when in doubt. The calculator applies to compact I-shapes bent about the strong axis, and the local buckling of the flanges and the web must be checked separately for slender sections. Check the shear, the deflection and the bearing too. The design of a real structure must be done by a licensed engineer.

The steel column capacity calculator covers compression members, the Euler buckling calculator covers elastic column buckling, the beam deflection calculator checks the serviceability and the bolt shear capacity calculator covers connections.

Frequently asked questions

What is lateral-torsional buckling?

When a beam is bent, the compression flange tends to buckle sideways like a column, and because the tension flange resists, the section twists as well. This is lateral-torsional buckling, and it can happen well before the steel yields in a long beam without lateral bracing. The strength is full for a short unbraced length, drops linearly in the inelastic zone and falls quickly in the elastic zone.

What are Lp and Lr?

Lp is the longest unbraced length at which the beam reaches the full plastic moment Mp = Fy Zx. Lr is the length above which the buckling is elastic and happens before the stresses reach the yield stress. Between Lp and Lr the strength is interpolated linearly from Mp down to 0.7 Fy Sx, and above Lr it is given by the elastic critical stress. These are formulas F2-5 and F2-6 of the AISC specification.

What is the Cb factor?

Cb accounts for the shape of the moment diagram between braces. A uniform moment is the worst case, with Cb = 1. A moment that varies along the unbraced length is less demanding on the compression flange, so Cb is larger, up to 3 at most, which increases the strength in the inelastic and elastic zones, never above Mp. A value of 1.0 is always conservative.

How is the unbraced length chosen?

The unbraced length is the distance between points where the compression flange is prevented from moving sideways, such as a floor deck properly connected, secondary beams with a lateral connection or bracing members. A concrete slab or a steel deck connected to the top flange usually braces a simple beam continuously, and then buckling does not govern. For cantilevers and for the bottom flange in compression at supports, the unbraced length needs more care.