Skip to content
Omnikalc

Stone column calculator: replacement ratio and settlement reduction of improved soft ground

Enter the diameter and spacing of the columns, the pattern, the stress concentration ratio and the untreated settlement to get the replacement ratio, the improvement factor, the treated settlement and the reduction.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

Value out of range

in

Value out of range

Results

Settlement improvement factor

1.38

Area replacement ratio
0.128
In the usual range of 0.10 to 0.35
Settlement of the treated ground
5.79 in
Reduction of settlement
27.7 %

The stone column calculator gives the area replacement ratio, the settlement improvement factor, the settlement of the treated ground and the reduction of the settlement for stone columns in soft soil, from the diameter, the spacing, the pattern and the stress concentration ratio.

How the calculation works

  • Enter the diameter and the spacing of the stone columns and choose the pattern, triangular or square.
  • Enter the stress concentration ratio, which is the stress on the column divided by the stress on the soil, and the settlement of the untreated ground.
  • The calculator finds the area replacement ratio, the settlement improvement factor by the equilibrium method, the settlement of the treated ground and the reduction of the settlement.

Example

Stone columns of 3 ft of diameter are placed in a triangular pattern at 8 ft. The area of a column is π × 3² / 4 = 7.07 ft² and the area of the unit cell is 0.866 × 8² = 55.4 ft², so the replacement ratio is 0.128. With a stress concentration ratio of 4, the improvement factor is 1 + 0.128 × (4 − 1) = 1.38. An untreated settlement of 8 in becomes 8 / 1.38 = 5.79 in, a reduction of 27.7 %.

Why it matters

The calculator helps geotechnical engineers, ground improvement contractors, designers and students to choose the diameter and the spacing of stone columns in a first design, and to see how much settlement a given replacement ratio can remove.

Good to know

Compare several spacings, use a conservative stress concentration ratio, and check the settlement of the layers below the columns, which the improvement does not reduce. Confirm the design with a load test on a trial column or a trial area before the construction.

The consolidation settlement calculator gives the settlement of the untreated clay, the bearing capacity calculator checks the foundation, the soil compaction calculator checks the fill and the elastic settlement calculator gives the immediate part.

Frequently asked questions

What are stone columns?

Stone columns, or vibro-replacement columns, are columns of compacted crushed stone or gravel built in soft clay, silt or loose sand with a vibrating probe. They are stiffer than the surrounding soil, so they take a larger part of the load, they act as vertical drains and they increase the bearing capacity. They are used under embankments, tanks, light buildings and for the reduction of the liquefaction risk.

What is the area replacement ratio?

The area replacement ratio as is the area of the stone column divided by the area of soil that it serves, the unit cell. For a triangular pattern, the unit cell is 0.866 s², and for a square pattern it is s², where s is the spacing between the columns. Typical ratios are 0.10 to 0.35. A higher ratio gives more improvement but needs more columns, and the cost grows quickly.

How is the improvement computed?

The calculator uses the equilibrium method with a constant stress concentration ratio n. The load is shared between the column and the soil, and the improvement factor, which is the settlement of the untreated ground divided by the treated one, is β = 1 + as (n − 1). The ratio n is often 2 to 5 for the clays, and the higher values are for stiff column in soft soil. More refined methods such as the one of Priebe use the friction angle of the stone.

What are the limits of the calculator?

The calculator gives a first estimate. It assumes a rigid raft or a uniform load, a constant stress ratio and an equal strain in the column and in the soil, so it does not include the bulging of the column, the time effect of the consolidation, the group effect at the edges, the settlement of the layer under the columns or the deformation of a footing. The design needs a geotechnical engineer and often a field trial.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.