The subsurface drain calculator gives the design inflow, the full-flow capacity, the velocity and the ratio of the inflow to the capacity of a perforated drain pipe, from the area drained, the drainage coefficient, the diameter, the slope and the roughness of the pipe.
How the calculation works
- Enter the area drained and choose the drainage coefficient, which is the depth of water to remove per day.
- Choose the diameter of the drain pipe, enter its slope and choose its Manning roughness.
- The calculator finds the design inflow, the full-flow capacity of the pipe, the velocity and the ratio of the inflow to the capacity.
Example
An area of 43,560 ft² (1 acre) drained at 1.0 in/day gives an inflow of 43,560 × 1 / 12 × 7.48 / 1,440 = 18.9 gpm. A pipe of 4 in at a slope of 0.5 % with n = 0.012 has a velocity of 1.486 / 0.012 × (4/48)^(2/3) × 0.005^0.5 = 1.67 ft/s and a full-flow capacity of 65.4 gpm. The ratio of the inflow to the capacity is 0.29.
Why it matters
The calculator helps site and drainage designers, landscape and foundation contractors, farmers and students to size an underdrain, to check that the pipe is not too small for the area and to compare the effect of the slope and of the diameter.
Good to know
Install the pipe with the holes down or according to the pipe maker, in a trench with clean gravel and a filter fabric, and keep a constant slope to a free outlet. Use cleanouts at the changes of direction, protect the outlet from the small animals and the sediment, and keep the drain away from the roots of the trees. Size the pipe with a margin, because a larger pipe costs little more than a pipe that clogs.
Related tools
The Manning equation calculator gives the flow of an open channel or a pipe, the pipe flow velocity calculator relates the flow and the pipe size, the Darcy’s law calculator gives the flow in the soil and the permeable pavement reservoir depth calculator sizes a stone reservoir.