Skip to content
Omnikalc

Thermal bridge heat loss calculator: heat lost through linear thermal bridges

Enter the linear transmittance Ψ, the length of the bridge, the temperature difference and the wall U-value and area to get the heat loss of the bridges, their share of the total and the effective U-value of the wall.

Updated on
Your inputs
Btu/h·ft·°F

Value out of range

ft

Value out of range

°F

Value out of range

Btu/h·ft²·°F

Value out of range

ft²

Value out of range

Results

Heat loss through the thermal bridges

542.9 Btu/h

Heat loss through the plain wall
2,480.4 Btu/h
Share of the total heat loss caused by the bridges
17.96 %
Thermal bridges add a notable share of the loss
Effective U-value of the wall with the bridges
0.0646 Btu/h·ft²·°F

The thermal bridge heat loss calculator gives the heat lost through linear thermal bridges from the linear transmittance Ψ, the length and the temperature difference, compares it with the plain wall and finds the effective U-value of the wall with its bridges.

How the calculation works

  • Enter the linear thermal transmittance Ψ of the detail (slab edge, window frame, balcony, corner) and the total length of that bridge.
  • Enter the temperature difference and the U-value and area of the plain wall.
  • The calculator finds the heat loss of the bridge, Φ = Ψ × L × ΔT, and of the plain wall, U × A × ΔT.
  • It gives the share of the total loss due to the bridges and the effective U-value of the wall including them.

Example

A wall of 1,300 ft² has a U-value of 0.053 Btu/h·ft²·°F and 260 ft of thermal bridge with Ψ = 0.058 Btu/h·ft·°F, with a temperature difference of 36 °F. The bridge loss is 0.058 × 260 × 36 = 542.9 Btu/h, and the plain wall loss is 0.053 × 1,300 × 36 = 2,480.4 Btu/h. The bridges are 542.9 / 3,023.3 = 17.96% of the loss, and the effective U-value is 0.053 + 0.058 × 260 / 1,300 = 0.0646 Btu/h·ft²·°F.

Why it matters

The calculator helps architects, energy modelers, builders and students to measure the weight of thermal bridges in a heat loss calculation, to compare construction details and to choose where a thermal-break or continuous insulation is worth the cost. It gives a quick estimate before a detailed simulation.

Good to know

Use the Ψ values given for your own detail, in the same unit system as the other inputs, and note whether the value is based on internal or external dimensions. Count each bridge only once, add all the bridges of the wall, and do not forget the point bridges, such as anchors, which are not included here. Check the inside surface temperature to avoid condensation and mold at the detail.

The wall U-value calculator gives the plain wall value, the heat loss calculator sizes the heating load, the air changes calculator covers ventilation losses and the window film calculator covers glazing improvements.

Frequently asked questions

What is a thermal bridge?

A thermal bridge is a part of the building envelope where the heat flows more easily than through the surrounding insulated area, because of a more conductive material or a break in the insulation. Typical examples are slab edges, balconies, lintels, window frames, wall corners and studs. They lose heat, lower the inside surface temperature and can cause condensation and mold.

What is the linear transmittance Ψ?

Ψ is the additional heat flow per meter of bridge and per degree of temperature difference, compared with the plain surfaces on either side. It is expressed in W/(m·K) or Btu/h·ft·°F. It comes from catalogs of thermal bridges, from a two-dimensional heat flow calculation, or from manufacturers of thermal-break products. A detail with a Ψ below 0.01 W/(m·K) is considered free of thermal bridge.

How do the bridges change the U-value?

The bridges add heat losses to the plain wall, so the effective U-value is the plain U-value plus the sum of Ψ × L divided by the wall area. In a well insulated wall the bridges can represent 15 to 30% of the loss, and the more a wall is insulated, the greater the relative weight of the bridges. For this reason the high-performance standards require a design without thermal bridges.

How can thermal bridges be reduced?

Place the insulation in a continuous layer on the outside of the structure, use thermal-break products at balconies and slab edges, insulate the window reveals and place the windows in the plane of the insulation, and avoid metal elements that cross the insulation. In a framed wall, a layer of continuous exterior insulation reduces the effect of the studs. A detailed design reduces the Ψ values considerably.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.